WEIGHTBEARING CT APPLICATIONS IN THE ANKLE SYNDESMOSIS

Despite various proposed measurement techniques for assessing syndesmosis integrity, a standardized protocol is lacking, and the existing literature reports inconsistent findings regarding normal and abnormal relationships between the fibula and tibia at the distal level. Therefore, this presentation aims to present an overview of two- (2D) and three-dimensional (3D) measurement methods utilized to evaluate syndesmosis integrity. A topical literature review was conducted, including studies employing 2D or 3D measurement techniques to quantify distal tibiofibular syndesmosis alignment on computed tomography (CT) or weight-bearing CT (WBCT) scans. A total of 49 eligible articles were included in this review. While most interclass correlation (ICC) values indicate favorable reliability, certain measurements involving multiple steps exhibited lower ICC values, potentially due to the learning curve associated with their implementation. Inconclusive results were obtained regarding the influence of age, sex, and height on syndesmotic measurements. No significant difference was observed between bilateral ankles, permitting the use of the opposite side as an internal control for comparison. There is a notable range of normal and pathological values, as evidenced by the standard deviation associated with each measurement. This review highlights the absence of a consensus on syndesmotic measurements for assessing integrity despite numerous CT scan studies. The diverse measurement techniques, complexity, and inconclusive findings present challenges in distinguishing between normal and pathological values in routine clinical practice. Promising advancements in novel 3D techniques offer potential for automated measurements and reduction of observer inaccuracies (figure 1 and 2), but further validation is needed. Volumetric measurements of the right and left distal tibiofibular joint (up to 1, 2 and 3 cm) and medial gutter in a patient with left Weber-B fracture

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-10-22
DOI
https://doi.org/10.1302/1358-992x.2025.9.023
Primary Topic
Nail Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

WEIGHTBEARING CT APPLICATIONS IN THE ANKLE SYNDESMOSIS

Matthias Peiffer
Orthopaedic Proceedings
Nail Diseases and Treatments
article

WEIGHTBEARING CT APPLICATIONS IN THE ANKLE SYNDESMOSIS

Matthias Peiffer
article en

Abstract

Despite various proposed measurement techniques for assessing syndesmosis integrity, a standardized protocol is lacking, and the existing literature reports inconsistent findings regarding normal and abnormal relationships between the fibula and tibia at the distal level. Therefore, this presentation aims to present an overview of two- (2D) and three-dimensional (3D) measurement methods utilized to evaluate syndesmosis integrity. A topical literature review was conducted, including studies employing 2D or 3D measurement techniques to quantify distal tibiofibular syndesmosis alignment on computed tomography (CT) or weight-bearing CT (WBCT) scans. A total of 49 eligible articles were included in this review. While most interclass correlation (ICC) values indicate favorable reliability, certain measurements involving multiple steps exhibited lower ICC values, potentially due to the learning curve associated with their implementation. Inconclusive results were obtained regarding the influence of age, sex, and height on syndesmotic measurements. No significant difference was observed between bilateral ankles, permitting the use of the opposite side as an internal control for comparison. There is a notable range of normal and pathological values, as evidenced by the standard deviation associated with each measurement. This review highlights the absence of a consensus on syndesmotic measurements for assessing integrity despite numerous CT scan studies. The diverse measurement techniques, complexity, and inconclusive findings present challenges in distinguishing between normal and pathological values in routine clinical practice. Promising advancements in novel 3D techniques offer potential for automated measurements and reduction of observer inaccuracies (figure 1 and 2), but further validation is needed. Volumetric measurements of the right and left distal tibiofibular joint (up to 1, 2 and 3 cm) and medial gutter in a patient with left Weber-B fracture

Orthopaedic ProceedingsVol. 107-B(SUPP_9)
Ghent University Hospital (BE)
Openalex Percentile: Top 60%
Nail Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.