DELAYED-TYPE HYPERSENSITIVITY TO IMPLANT MATERIALS: ALTERNATIVES IN KNEE ARTHROPLASTY

Knee Implants are usually made of CoCr28Mo6 or TiAl6V4 alloys or combinations of both materials in modular junctions. Particles and metal ions from knee implants are always released after implantation, either as a result of mechanical (wear) or electrochemical processes (corrosion). Total knee arthroplasties (TKA) are very effective treatment options for advanced osteoarthritis of the joints with overall low revision rates [1–4]. However, biological reactions in patients (allergy, inflammatory response), caused by the release of metal particles and ions, have been reported [4–8]. An overview will be given about alternative implant materials and their biotribological properties, biological reactions and clinical results to substantially reduce metal ion release in knee arthroplasty. Methods. Implant materials are usually well tolerated, but if a critical metal ion concentration is exceeded, local or systemic reactions can occur. The released metal particles and metal ions accumulate around affected joints as well as in body fluids and distant organs. Local tissue reactions to metal particles around joint arthroplasties have been described by the term “adverse reactions to metal debris”. Based on the alloy composition of established implant materials their biotribological behaviour with release of metal debris and Co, Cr, Mo, Ni, Ti ions will be demonstrated in meaningful examples with a focus on adverse biological reactions, clinical findings in patients with suspected metal ion hypersensitivity and implant registry results. If patients present with a confirmed metal allergy, in TKA a ZrN-multilayer-coated or oxidized zirconium implant is currently the best option [5,6,8]. To address hyper-sensitivity reactions to bone cement constituents [9], up-coming innovative implant technologies based on ceramic-coated 3D-printed TiAl6V4-alloy with cementless bone fixation represent a future perspective.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-10-22
DOI
https://doi.org/10.1302/1358-992x.2025.9.059
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DELAYED-TYPE HYPERSENSITIVITY TO IMPLANT MATERIALS: ALTERNATIVES IN KNEE ARTHROPLASTY

Peter Thomas, Berna Richter, Jörg Lützner, Thomas M. Grupp et al.
Orthopaedic Proceedings
Total Knee Arthroplasty Outcomes
article

DELAYED-TYPE HYPERSENSITIVITY TO IMPLANT MATERIALS: ALTERNATIVES IN KNEE ARTHROPLASTY

Peter Thomas, Berna Richter, Jörg Lützner, Thomas M. Grupp, Stefan Landgraeber, Ana Laura Puente Reyna, Alexander Giurea, S.V. Giridhar Reddy, Julius C. Dohm
article en

Abstract

Knee Implants are usually made of CoCr28Mo6 or TiAl6V4 alloys or combinations of both materials in modular junctions. Particles and metal ions from knee implants are always released after implantation, either as a result of mechanical (wear) or electrochemical processes (corrosion). Total knee arthroplasties (TKA) are very effective treatment options for advanced osteoarthritis of the joints with overall low revision rates [1–4]. However, biological reactions in patients (allergy, inflammatory response), caused by the release of metal particles and ions, have been reported [4–8]. An overview will be given about alternative implant materials and their biotribological properties, biological reactions and clinical results to substantially reduce metal ion release in knee arthroplasty. Methods. Implant materials are usually well tolerated, but if a critical metal ion concentration is exceeded, local or systemic reactions can occur. The released metal particles and metal ions accumulate around affected joints as well as in body fluids and distant organs. Local tissue reactions to metal particles around joint arthroplasties have been described by the term “adverse reactions to metal debris”. Based on the alloy composition of established implant materials their biotribological behaviour with release of metal debris and Co, Cr, Mo, Ni, Ti ions will be demonstrated in meaningful examples with a focus on adverse biological reactions, clinical findings in patients with suspected metal ion hypersensitivity and implant registry results. If patients present with a confirmed metal allergy, in TKA a ZrN-multilayer-coated or oxidized zirconium implant is currently the best option [5,6,8]. To address hyper-sensitivity reactions to bone cement constituents [9], up-coming innovative implant technologies based on ceramic-coated 3D-printed TiAl6V4-alloy with cementless bone fixation represent a future perspective.

Orthopaedic ProceedingsVol. 107-B(SUPP_9)
Australian Orthopaedic Association (AU), Joint Replacement Institute (US), University Hospital Carl Gustav Carus (DE), Technische Universität Dresden (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 53%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.