Single center experience with covered stent closure of sinus venosus atrial septal defect

To evaluate the feasibility, safety, and short-term outcomes of transcatheter closure of sinus venosus atrial septal defect (SVASD) using covered stents. We conducted an institutional retrospective analysis of 24 consecutive patients aged 15-70 years with superior SVASD and significant left-to-right shunting (QP/QS ≥ 1.5), who underwent percutaneous closure using covered stents between June 2021 and December 2023. Pre-procedural imaging included transesophageal echocardiography and cardiac Computed Tomography angiography (CTA). Procedural details, technical success, and echocardiographic parameters were recorded. Post-procedural outcomes were assessed with transthoracic echocardiography and/or CTA. The Patients' median age was 38 years (IQR: 28-53), and 50% were female. Median Atrial Septal Defect (ASD) size was 15 mm (IQR: 11-19), and median QP/QS ratio decreased from 1.8 (IQR: 1.7-1.95) to 1.1 (IQR: 1.0-1.25) after closure (p < 0.001). Covered stents were used in all cases, and 13 patients (54.1%) required additional non-covered stent support. Technical success was achieved in 96% of patients, with one case of device embolization requiring surgical intervention. Minor complications occurred in 7 patients (29.1%), including hematoma and asymptomatic thrombosis. No mortality was observed. At 3 months, right ventricular dysfunction and enlargement significantly improved (p = 0.004 and p = 0.001, respectively), while right atrial size remained unchanged (p = 0.317). Catheter-based repair of SVASD is feasible, safe, and effective with a low rate of complications. This approach may offer a minimally invasive alternative to surgery in anatomically suitable patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-22
DOI
https://doi.org/10.1038/s41598-025-20598-2
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single center experience with covered stent closure of sinus venosus atrial septal defect

Zahra Khajali, Mohammadreza Baay, Hamidreza Pouraliakbar, Mahboobeh Gholipour et al.
Scientific Reports
Cardiovascular and Diving-Related Complications
article

Single center experience with covered stent closure of sinus venosus atrial septal defect

Zahra Khajali, Mohammadreza Baay, Hamidreza Pouraliakbar, Mahboobeh Gholipour, А.Л. Талис, Ata Firuzi, Armin Elahifar, Ehsan Khalilipur, Hooman Bakhshande, Sedigheh Saedi, Elmira Aghaee kiasaraee
article en

Abstract

To evaluate the feasibility, safety, and short-term outcomes of transcatheter closure of sinus venosus atrial septal defect (SVASD) using covered stents. We conducted an institutional retrospective analysis of 24 consecutive patients aged 15-70 years with superior SVASD and significant left-to-right shunting (QP/QS ≥ 1.5), who underwent percutaneous closure using covered stents between June 2021 and December 2023. Pre-procedural imaging included transesophageal echocardiography and cardiac Computed Tomography angiography (CTA). Procedural details, technical success, and echocardiographic parameters were recorded. Post-procedural outcomes were assessed with transthoracic echocardiography and/or CTA. The Patients' median age was 38 years (IQR: 28-53), and 50% were female. Median Atrial Septal Defect (ASD) size was 15 mm (IQR: 11-19), and median QP/QS ratio decreased from 1.8 (IQR: 1.7-1.95) to 1.1 (IQR: 1.0-1.25) after closure (p < 0.001). Covered stents were used in all cases, and 13 patients (54.1%) required additional non-covered stent support. Technical success was achieved in 96% of patients, with one case of device embolization requiring surgical intervention. Minor complications occurred in 7 patients (29.1%), including hematoma and asymptomatic thrombosis. No mortality was observed. At 3 months, right ventricular dysfunction and enlargement significantly improved (p = 0.004 and p = 0.001, respectively), while right atrial size remained unchanged (p = 0.317). Catheter-based repair of SVASD is feasible, safe, and effective with a low rate of complications. This approach may offer a minimally invasive alternative to surgery in anatomically suitable patients.

Scientific ReportsVol. 15(1)
Guilan University of Medical Sciences (IR), Shaheed Rajaei Cardiovascular Medical and Research Center (IR)
Openalex Percentile: Top 57%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.