Predictive value of tidal volume and peak inspiratory pressure in normal frequency jet ventilation

Normal frequency jet ventilation (NFJV) is commonly used during rigid bronchoscopy; however, airway opening does not reliably measure or predict tidal volume (V<sub>T</sub>) or peak inspiratory pressure (PIP). This study aimed to investigate the comprehensive effects on V<sub>T</sub> and PIP concerning key variables, including driving pressure (DP<sub>pipeline</sub>), frequency (F<sub>jet</sub>), needle inner diameter (ID<sub>needle</sub>), and lung dynamic compliance (C<sub>dyn</sub>). Three jet needles (N<sub>1</sub>, N<sub>2</sub>, and N<sub>3</sub>) with different internal diameters (1.2-1.9 mm) were used to deliver jet ventilation via a rigid bronchoscope at DPs of 0.6-1.6 bar and frequencies of 10-60 min⁻¹. Airway pressure (Paw) was measured near the tracheal prominence of the simulated lung. Expiratory gas flow was diverted into a dedicated collection chamber fitted with a solenoid valve over a one-minute period, and the collected volume was measured as minute volume (MV). ①. Statistical analysis of the two lung models revealed consistent findings: both V<sub>T</sub> and PIP values in N<sub>2</sub> and N<sub>3</sub> demonstrated statistically significant differences compared to N<sub>1</sub> (P < 0.05). Additionally, significant differences in the V<sub>T</sub> and PIP values were observed between N<sub>2</sub> and N<sub>3</sub> (P < 0.05). ②. Multiple linear regression analyses indicated that DP<sub>pipeline</sub>, F<sub>jet</sub>, and ID<sub>needle</sub> had statistically significant effects on V<sub>T</sub> and PIP (P < 0.05). Conversely, C<sub>dyn</sub> significantly affected V<sub>T</sub> (P < 0.05) but did not have a significant impact on PIP (P > 0.05). The primary variables exerting a significant influence on V<sub>T</sub> and PIP were DP<sub>pipeline</sub>, F<sub>jet</sub>, and ID<sub>needle</sub>. Furthermore, C<sub>dyn</sub> significantly affected V<sub>T</sub> but not PIP. V<sub>T</sub> and PIP can be accurately predicted using regression equations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-22
DOI
https://doi.org/10.1038/s41598-025-20681-8
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictive value of tidal volume and peak inspiratory pressure in normal frequency jet ventilation

Jianliang Peng, Jing Lv
Scientific Reports
Respiratory Support and Mechanisms
article

Predictive value of tidal volume and peak inspiratory pressure in normal frequency jet ventilation

Jianliang Peng, Jing Lv
article en

Abstract

Normal frequency jet ventilation (NFJV) is commonly used during rigid bronchoscopy; however, airway opening does not reliably measure or predict tidal volume (V<sub>T</sub>) or peak inspiratory pressure (PIP). This study aimed to investigate the comprehensive effects on V<sub>T</sub> and PIP concerning key variables, including driving pressure (DP<sub>pipeline</sub>), frequency (F<sub>jet</sub>), needle inner diameter (ID<sub>needle</sub>), and lung dynamic compliance (C<sub>dyn</sub>). Three jet needles (N<sub>1</sub>, N<sub>2</sub>, and N<sub>3</sub>) with different internal diameters (1.2-1.9 mm) were used to deliver jet ventilation via a rigid bronchoscope at DPs of 0.6-1.6 bar and frequencies of 10-60 min⁻¹. Airway pressure (Paw) was measured near the tracheal prominence of the simulated lung. Expiratory gas flow was diverted into a dedicated collection chamber fitted with a solenoid valve over a one-minute period, and the collected volume was measured as minute volume (MV). ①. Statistical analysis of the two lung models revealed consistent findings: both V<sub>T</sub> and PIP values in N<sub>2</sub> and N<sub>3</sub> demonstrated statistically significant differences compared to N<sub>1</sub> (P < 0.05). Additionally, significant differences in the V<sub>T</sub> and PIP values were observed between N<sub>2</sub> and N<sub>3</sub> (P < 0.05). ②. Multiple linear regression analyses indicated that DP<sub>pipeline</sub>, F<sub>jet</sub>, and ID<sub>needle</sub> had statistically significant effects on V<sub>T</sub> and PIP (P < 0.05). Conversely, C<sub>dyn</sub> significantly affected V<sub>T</sub> (P < 0.05) but did not have a significant impact on PIP (P > 0.05). The primary variables exerting a significant influence on V<sub>T</sub> and PIP were DP<sub>pipeline</sub>, F<sub>jet</sub>, and ID<sub>needle</sub>. Furthermore, C<sub>dyn</sub> significantly affected V<sub>T</sub> but not PIP. V<sub>T</sub> and PIP can be accurately predicted using regression equations.

Scientific ReportsVol. 15(1)
First Affiliated Hospital of Xiamen University (CN), The Second Affiliated Hospital of Xiamen Medical College
Openalex Percentile: Top 57%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.