Development of a sensitive, reliable, and cost-effective sandwich ELISA for quantitative measurement of human hemoglobin A2 in beta-thalassemia diagnosis

Introduction: Accurate quantification of hemoglobin A2 (HbA2) is essential for the diagnosis and monitoring of beta-thalassemia and related hemoglobinopathies. Existing methods, such as HPLC and capillary electrophoresis (CE), are effective but require expensive instrumentation. We developed and validated a cost-effective and sensitive sandwich ELISA for measuring HbA2 levels in human blood samples. Methods: A pair of specific monoclonal antibodies against distinct epitopes of HbA2 was used to establish a sandwich ELISA. The assay was optimized for analytical performance, including sensitivity, specificity, linearity, and intra-/inter-assay precision. Validation was conducted using both standard recombinant HbA2 and clinical samples from healthy donors and confirmed beta-thalassemia patients. Findings: The assay demonstrated a lower limit of detection (LOD) of 0.1% and a quantification range of 0.1–10%. Coefficients of variation (CVs) were below 10% across all concentrations tested. HbA2 levels in beta-thalassemia patients were significantly elevated (P<0.001) compared to healthy controls, confirming the assay’s diagnostic potential. Conclusion: This optimized sandwich ELISA offers a reliable, affordable, and scalable alternative for quantifying HbA2 in clinical laboratories, particularly in resource-limited settings. Its high specificity and reproducibility make it a promising tool for the diagnosis and follow-up of beta-thalassemia.

Authors

Institutions

Publication Details

Journal
Biomedicine Advances
Published
2025-10-20
DOI
https://doi.org/10.34172/bma.35
Primary Topic
Hemoglobinopathies and Related Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a sensitive, reliable, and cost-effective sandwich ELISA for quantitative measurement of human hemoglobin A2 in beta-thalassemia diagnosis

Samaneh Hosseinzadeh, S. Adeleh Razavi, Mehdi Hedayati, Safura Pakizehkar et al.
Biomedicine Advances
Hemoglobinopathies and Related Disorders
article

Development of a sensitive, reliable, and cost-effective sandwich ELISA for quantitative measurement of human hemoglobin A2 in beta-thalassemia diagnosis

Samaneh Hosseinzadeh, S. Adeleh Razavi, Mehdi Hedayati, Safura Pakizehkar, Laleh Hoghooghi Rad, Hoda Gholab Ghadaksaz
article en

Abstract

Introduction: Accurate quantification of hemoglobin A2 (HbA2) is essential for the diagnosis and monitoring of beta-thalassemia and related hemoglobinopathies. Existing methods, such as HPLC and capillary electrophoresis (CE), are effective but require expensive instrumentation. We developed and validated a cost-effective and sensitive sandwich ELISA for measuring HbA2 levels in human blood samples. Methods: A pair of specific monoclonal antibodies against distinct epitopes of HbA2 was used to establish a sandwich ELISA. The assay was optimized for analytical performance, including sensitivity, specificity, linearity, and intra-/inter-assay precision. Validation was conducted using both standard recombinant HbA2 and clinical samples from healthy donors and confirmed beta-thalassemia patients. Findings: The assay demonstrated a lower limit of detection (LOD) of 0.1% and a quantification range of 0.1–10%. Coefficients of variation (CVs) were below 10% across all concentrations tested. HbA2 levels in beta-thalassemia patients were significantly elevated (P<0.001) compared to healthy controls, confirming the assay’s diagnostic potential. Conclusion: This optimized sandwich ELISA offers a reliable, affordable, and scalable alternative for quantifying HbA2 in clinical laboratories, particularly in resource-limited settings. Its high specificity and reproducibility make it a promising tool for the diagnosis and follow-up of beta-thalassemia.

Biomedicine AdvancesVol. 2(4)
Research Institute for Endocrine Sciences (IR), Shahid Beheshti University of Medical Sciences (IR)
National Institute for Medical Research Development
Openalex Percentile: Top 59%
Hemoglobinopathies and Related Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.