Developing A Custom-Built Metal Aerosol Processing Chamber: Analysis of Aerosol Coagulation at Low Humidities

Abstract. We have developed an intermediate size (906 L) aerosol processing chamber, and this work reports on the design and initial characterization of dry aerosol experiments. Specifically, we are determining wall-loss and coagulation correction factors using the observed size distribution measurements for surrogates of common aerosol classes: sodium chloride, sucrose, and biomass burning aerosol smoke. Results show that, on average, sodium chloride, sucrose, and smoke wall-loss rates converge to similar values on relatively short time scales (< 1 h). The fitted coagulation correction factor, WC-1, for smoke particles (1.23 ± 0.312), indicates that on average they adhere to each other more than sodium chloride (0.969 ± 0.524) and sucrose (1.16 ± 1.38). The relative uncertainty is high for the coagulation correction, but it is consistent with our Monte Carlo error analysis. This study lays the foundation for future experiments at elevated humidity and supersaturation conditions to characterize the influence of particle shape on coagulation and cloud parameters.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-10-22
DOI
https://doi.org/10.5194/amt-18-5705-2025
Primary Topic
Particle Dynamics in Fluid Flows
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Developing A Custom-Built Metal Aerosol Processing Chamber: Analysis of Aerosol Coagulation at Low Humidities

Katherine Benedict, Kyle Gorkowski, Nevil Franco
Atmospheric measurement techniques
Particle Dynamics in Fluid Flows
article

Developing A Custom-Built Metal Aerosol Processing Chamber: Analysis of Aerosol Coagulation at Low Humidities

Katherine Benedict, Kyle Gorkowski, Nevil Franco
article en

Abstract

Abstract. We have developed an intermediate size (906 L) aerosol processing chamber, and this work reports on the design and initial characterization of dry aerosol experiments. Specifically, we are determining wall-loss and coagulation correction factors using the observed size distribution measurements for surrogates of common aerosol classes: sodium chloride, sucrose, and biomass burning aerosol smoke. Results show that, on average, sodium chloride, sucrose, and smoke wall-loss rates converge to similar values on relatively short time scales (< 1 h). The fitted coagulation correction factor, WC-1, for smoke particles (1.23 ± 0.312), indicates that on average they adhere to each other more than sodium chloride (0.969 ± 0.524) and sucrose (1.16 ± 1.38). The relative uncertainty is high for the coagulation correction, but it is consistent with our Monte Carlo error analysis. This study lays the foundation for future experiments at elevated humidity and supersaturation conditions to characterize the influence of particle shape on coagulation and cloud parameters.

Atmospheric measurement techniquesVol. 18(20)
Los Alamos National Laboratory (US)
U.S. Department of Energy, National Nuclear Security Administration, Los Alamos National Laboratory
Openalex Percentile: Top 62%
Particle Dynamics in Fluid Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.