CERA Detection and Stability in Blood Versus Urine

Erythropoietin receptor agonists (ERAs), including continuous erythropoietin receptor activators (CERAs), are potent blood doping substances used to enhance endurance performance by stimulating erythropoiesis. While traditionally detected through direct analysis of urine or serum samples using sarcosyl-polyacrylamide gel electrophoresis (SAR-PAGE) and western blotting, the slow urinary elimination of third-generation ERAs like CERA has shifted anti-doping strategies toward serum-based detection. This study compared the detectability and stability of CERA in urine and serum matrices and evaluated the added value of combining direct detection with hematological profiling. Using samples from a controlled CERA administration study and an authentic case example, we assessed CERA detection in serum, urine, and simulated dried blood spot (DBS) matrices (Tasso-M20). Additionally, we conducted stability experiments by incubating spiked matrices at 37°C for up to 72 h. Our results confirmed the superior stability and consistent detectability of CERA in serum and DBS compared with urine. Moreover, hematological alterations such as increased reticulocytes percentage flagged by the Athlete Biological Passport (ABP) supported targeted serum testing, leading to the successful detection of CERA. These findings highlight the importance of systematic blood collection for both direct and indirect detection strategies. Furthermore, DBS samples showed promising analytical performance and resistance to elevated temperature, suggesting their utility as minimally invasive alternatives in anti-doping programs. Overall, our study reinforces the relevance of blood matrices in the detection of CERA and advocates for the broader integration of blood-based strategies in targeting doping practices with ERAs.

Authors

Institutions

Publication Details

Journal
Drug Testing and Analysis
Published
2025-10-21
DOI
https://doi.org/10.1002/dta.3960
Citations
1
Primary Topic
Erythropoietin and Anemia Treatment
Type
article
Field-Weighted Citation Impact
1.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CERA Detection and Stability in Blood Versus Urine

Tiia Kuuranne, Lasse Vestli Bækken, Olivier Salamin, Nicolas Leuenberger et al.
1 citations
Drug Testing and Analysis
Erythropoietin and Anemia Treatment
1.77
article

CERA Detection and Stability in Blood Versus Urine

Tiia Kuuranne, Lasse Vestli Bækken, Olivier Salamin, Nicolas Leuenberger, Joséphine Chappuis
article en
1 citations

Abstract

Erythropoietin receptor agonists (ERAs), including continuous erythropoietin receptor activators (CERAs), are potent blood doping substances used to enhance endurance performance by stimulating erythropoiesis. While traditionally detected through direct analysis of urine or serum samples using sarcosyl-polyacrylamide gel electrophoresis (SAR-PAGE) and western blotting, the slow urinary elimination of third-generation ERAs like CERA has shifted anti-doping strategies toward serum-based detection. This study compared the detectability and stability of CERA in urine and serum matrices and evaluated the added value of combining direct detection with hematological profiling. Using samples from a controlled CERA administration study and an authentic case example, we assessed CERA detection in serum, urine, and simulated dried blood spot (DBS) matrices (Tasso-M20). Additionally, we conducted stability experiments by incubating spiked matrices at 37°C for up to 72 h. Our results confirmed the superior stability and consistent detectability of CERA in serum and DBS compared with urine. Moreover, hematological alterations such as increased reticulocytes percentage flagged by the Athlete Biological Passport (ABP) supported targeted serum testing, leading to the successful detection of CERA. These findings highlight the importance of systematic blood collection for both direct and indirect detection strategies. Furthermore, DBS samples showed promising analytical performance and resistance to elevated temperature, suggesting their utility as minimally invasive alternatives in anti-doping programs. Overall, our study reinforces the relevance of blood matrices in the detection of CERA and advocates for the broader integration of blood-based strategies in targeting doping practices with ERAs.

Drug Testing and AnalysisVol. 18(1)
Oslo University Hospital (NO), University Centre of Legal Medicine (CH), University of Lausanne (CH)
Openalex Percentile: Top 12%
Erythropoietin and Anemia Treatment
1.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.