Color stability of composite resins with different photoinitiator systems when subjected to water aging: an in vitro study.

The objective of this study was to evaluate the color stability of composite resins with different photoinitiator systems when subjected to water aging for 28 days. A total of 48 disc-shaped specimens (1.5 mm in diameter × 2.0 mm thick) of 3 commercially available composite resins (n = 16 per group) were fabricated in custom acrylic molds. Each of the composite resins is formulated with a distinct photoinitiator system: diphenyl (2,4,6-trimethylbenzoyl) phosphineoxide (TPO), bis(4-methoxybenzoyl) diethylgermanium (Ivocerin), or camphorquinone (CQ). The specimens were polymerized with an LED curing unit and stored in a dark room for 24 hours. Baseline color measurements based on International Commission on Illumination (CIE) L*a*b* parameters were recorded with a spectrophotometer. To evaluate the effects of water aging, specimens were immersed in a thermostatic water bath at 37°C for 28 days; water was replaced every 7 days. Following immersion, specimens were remeasured spectrophotometrically to assess color change. Color differences between baseline values and values obtained after the aging procedures were calculated for each specimen and statistically analyzed using analysis of variance and post hoc Tukey tests. After 28 days of water aging, all specimens exhibited statistically significant (P < 0.001) overall color changes (ΔE*), underscoring a pronounced decline in color stability. A statistically significant difference (P < 0.001) in ΔE* was observed between the TPO and Ivocerin groups, with TPO presenting maximum preservation of color stability. No statistically significant difference (P > 0.05) was found between the TPO and CQ groups or the Ivocerin and CQ groups, suggesting somewhat comparable color stability in these groups. Despite color alterations across all materials, the TPO-based composite resin exhibited superior color stability when compared with the Ivocerin- and CQ-based resins in the study, suggesting that TPO may offer enhanced long-term esthetic durability in clinical applications.

Authors

Publication Details

Journal
PubMed
Published
2025-10-20
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Color stability of composite resins with different photoinitiator systems when subjected to water aging: an in vitro study.

Anu Vashisht, Ajay Singh Rao, Garima Poddar, Suparna Saha et al.
PubMed
Dental materials and restorations
article

Color stability of composite resins with different photoinitiator systems when subjected to water aging: an in vitro study.

Anu Vashisht, Ajay Singh Rao, Garima Poddar, Suparna Saha, Rolly Agarwal, Manasi Kewlani
article en

Abstract

The objective of this study was to evaluate the color stability of composite resins with different photoinitiator systems when subjected to water aging for 28 days. A total of 48 disc-shaped specimens (1.5 mm in diameter × 2.0 mm thick) of 3 commercially available composite resins (n = 16 per group) were fabricated in custom acrylic molds. Each of the composite resins is formulated with a distinct photoinitiator system: diphenyl (2,4,6-trimethylbenzoyl) phosphineoxide (TPO), bis(4-methoxybenzoyl) diethylgermanium (Ivocerin), or camphorquinone (CQ). The specimens were polymerized with an LED curing unit and stored in a dark room for 24 hours. Baseline color measurements based on International Commission on Illumination (CIE) L*a*b* parameters were recorded with a spectrophotometer. To evaluate the effects of water aging, specimens were immersed in a thermostatic water bath at 37°C for 28 days; water was replaced every 7 days. Following immersion, specimens were remeasured spectrophotometrically to assess color change. Color differences between baseline values and values obtained after the aging procedures were calculated for each specimen and statistically analyzed using analysis of variance and post hoc Tukey tests. After 28 days of water aging, all specimens exhibited statistically significant (P < 0.001) overall color changes (ΔE*), underscoring a pronounced decline in color stability. A statistically significant difference (P < 0.001) in ΔE* was observed between the TPO and Ivocerin groups, with TPO presenting maximum preservation of color stability. No statistically significant difference (P > 0.05) was found between the TPO and CQ groups or the Ivocerin and CQ groups, suggesting somewhat comparable color stability in these groups. Despite color alterations across all materials, the TPO-based composite resin exhibited superior color stability when compared with the Ivocerin- and CQ-based resins in the study, suggesting that TPO may offer enhanced long-term esthetic durability in clinical applications.

PubMedVol. 73(6)
Openalex Percentile: Top 68%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.