Evaluation of a sample-to-answer real-time PCR assay for enterovirus detection in cerebrospinal fluid

Enteroviruses frequently cause aseptic meningitis, necessitating differentiation from bacterial meningitis to avoid unnecessary antimicrobial treatment and improve patient management. Polymerase chain reaction (PCR) remains the gold standard for enterovirus detection in cerebrospinal fluid (CSF) due to its high sensitivity and rapid turnaround time. The discontinuation of the Cepheid Xpert EV assay has created a gap in diagnostics. This study aimed to optimize two laboratory-developed real-time PCR assays using Diasorin direct amplification disc (DAD) and universal disc (UD) methods compared to the previously standard Cepheid Xpert EV assay. A total of 87 clinical CSF specimens were tested to assess sensitivity, specificity, and overall performance. There was no significant difference between the performance of the three assays compared to standard of care results. The Xpert EV and DAD methods had a 79.6% positive agreement, while the UD method had an 86.4% positive agreement. All methods achieved 100% negative agreement. Specificity testing against non-enteroviral pathogens confirmed no cross-reactivity. The estimated limit of detection was 100 copies/mL for Xpert EV, 250 copies/mL for UD, and 1,000 copies/mL for DAD, though clinical sensitivity remained high. Blood contamination affected the DAD assay but not the UD method due to its RNA extraction step. This study demonstrates the potential of DAD and UD methods as viable alternatives for rapid enterovirus detection in CSF, essential for patient management following the discontinuation of the Xpert EV assay. Further validation and comparison are needed for broader clinical applications.IMPORTANCERapid and accurate detection of enteroviruses in cerebrospinal fluid is crucial for patient management in cases of aseptic meningitis, especially following the discontinuation of the Cepheid Xpert EV assay. This study evaluates two laboratory-developed real-time PCR assays utilizing Diasorin direct amplification disc and universal disc methods, demonstrating their potential as viable alternatives for enterovirus detection with high sensitivity and specificity.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Microbiology
Published
2025-10-21
DOI
https://doi.org/10.1128/jcm.00864-25
Primary Topic
Viral Infections and Immunology Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a sample-to-answer real-time PCR assay for enterovirus detection in cerebrospinal fluid

L.A. Hughes, K.E. Wade, Neil W. Anderson, Bijal A. Parikh et al.
Journal of Clinical Microbiology
Viral Infections and Immunology Research
article

Evaluation of a sample-to-answer real-time PCR assay for enterovirus detection in cerebrospinal fluid

L.A. Hughes, K.E. Wade, Neil W. Anderson, Bijal A. Parikh, Grace Perkins, Jennifer Swink
article en

Abstract

Enteroviruses frequently cause aseptic meningitis, necessitating differentiation from bacterial meningitis to avoid unnecessary antimicrobial treatment and improve patient management. Polymerase chain reaction (PCR) remains the gold standard for enterovirus detection in cerebrospinal fluid (CSF) due to its high sensitivity and rapid turnaround time. The discontinuation of the Cepheid Xpert EV assay has created a gap in diagnostics. This study aimed to optimize two laboratory-developed real-time PCR assays using Diasorin direct amplification disc (DAD) and universal disc (UD) methods compared to the previously standard Cepheid Xpert EV assay. A total of 87 clinical CSF specimens were tested to assess sensitivity, specificity, and overall performance. There was no significant difference between the performance of the three assays compared to standard of care results. The Xpert EV and DAD methods had a 79.6% positive agreement, while the UD method had an 86.4% positive agreement. All methods achieved 100% negative agreement. Specificity testing against non-enteroviral pathogens confirmed no cross-reactivity. The estimated limit of detection was 100 copies/mL for Xpert EV, 250 copies/mL for UD, and 1,000 copies/mL for DAD, though clinical sensitivity remained high. Blood contamination affected the DAD assay but not the UD method due to its RNA extraction step. This study demonstrates the potential of DAD and UD methods as viable alternatives for rapid enterovirus detection in CSF, essential for patient management following the discontinuation of the Xpert EV assay. Further validation and comparison are needed for broader clinical applications.IMPORTANCERapid and accurate detection of enteroviruses in cerebrospinal fluid is crucial for patient management in cases of aseptic meningitis, especially following the discontinuation of the Cepheid Xpert EV assay. This study evaluates two laboratory-developed real-time PCR assays utilizing Diasorin direct amplification disc and universal disc methods, demonstrating their potential as viable alternatives for enterovirus detection with high sensitivity and specificity.

Journal of Clinical MicrobiologyVol. 63(11)
Barnes-Jewish Hospital (US), Washington University in St. Louis (US), Case Western Reserve University (US)
Openalex Percentile: Top 55%
Viral Infections and Immunology Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.