A Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants

This study proposes a hybrid method that combines a Genetic Algorithm (GA) with Digital Twin (DT) technology to address nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, the GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitored the grid conditions and performed rolling dispatch to mitigate the residual reactive power caused by nighttime voltage fluctuations. Simulation results show that GA-based optimization reduces line losses from 0.346 to 0.2818 kW (18.6% reduction) and helps alleviate inverter thermal stress. When integrated with DTs, the method further improves voltage stability and demonstrates a strong adaptive control capability. The proposed GA–DT strategy can also be regarded as a potential AIoT application in PV plants, with the potential to reduce operational and maintenance costs and enhance the system reliability in the future.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-10-21
DOI
https://doi.org/10.3390/app152011282
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants

Yu-Ming Liu, Hung-Cheng Chen, Cheng‐Chien Kuo
Applied Sciences
Photovoltaic System Optimization Techniques
article

A Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants

Yu-Ming Liu, Hung-Cheng Chen, Cheng‐Chien Kuo
article en

Abstract

This study proposes a hybrid method that combines a Genetic Algorithm (GA) with Digital Twin (DT) technology to address nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, the GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitored the grid conditions and performed rolling dispatch to mitigate the residual reactive power caused by nighttime voltage fluctuations. Simulation results show that GA-based optimization reduces line losses from 0.346 to 0.2818 kW (18.6% reduction) and helps alleviate inverter thermal stress. When integrated with DTs, the method further improves voltage stability and demonstrates a strong adaptive control capability. The proposed GA–DT strategy can also be regarded as a potential AIoT application in PV plants, with the potential to reduce operational and maintenance costs and enhance the system reliability in the future.

Applied SciencesVol. 15(20)
National Taiwan University of Science and Technology (TW), National Chin-Yi University of Technology (TW)
Strong
Openalex Percentile: Top 79%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.