A Fluorescence-Based Histidine-Imidazole Polyacrylamide Gel Electrophoresis (HI-PAGE) Method for Rapid and Practical Lipoprotein Profiling and LDL-C Quantification in Clinical Samples

<b>Background</b>: Polyacrylamide gel electrophoresis (PAGE) has long been used for lipoprotein analysis, enabling the separation and profiling of lipoprotein fractions such as LDL and HDL. However, conventional disc PAGE systems are limited by low throughput and inability to directly compare multiple samples under identical conditions. Alternative methods, including high-performance liquid chromatography and agarose gel electrophoresis, require specialized equipment and expertise, limiting their clinical utility. <b>Methods</b>: We present a colorimetric and fluorescence-based histidine-imidazole PAGE (HI-PAGE) system that provides rapid, cost-effective, and reproducible separation and profiling of lipoproteins in human serum. By combining electrophoretic separation with lipid-specific fluorescent staining using Nile Red, the fluorescence-based HI-PAGE (fHI-PAGE) not only visualizes distinct migration patterns of lipoprotein fractions, but also enables the quantification of LDL-cholesterol (LDL-C). Clear resolution of LDL and other lipoprotein fractions was achieved within 1 h without band distortion, allowing for direct comparison of multiple samples on a single gel. <b>Results</b>: We validated fHI-PAGE using serum from healthy individuals and patients, demonstrating that its fluorescence-based detection was more sensitive than conventional Sudan Black B staining while providing LDL-C estimates concordant with values calculated by the Friedewald formula. Moreover, fHI-PAGE proved advantageous in cases of hypertriglyceridemia, where Friedewald calculations are unreliable. <b>Conclusions</b>: These findings establish fHI-PAGE as a practical and clinically applicable platform for simultaneous lipoprotein profiling and LDL-C quantification.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-10-21
DOI
https://doi.org/10.3390/biomedicines13102560
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fluorescence-Based Histidine-Imidazole Polyacrylamide Gel Electrophoresis (HI-PAGE) Method for Rapid and Practical Lipoprotein Profiling and LDL-C Quantification in Clinical Samples

Yasuhiro Takenaka, Masa‐Aki Ikeda, Yoshihiko Kakinuma, Ikuo Inoue
Biomedicines
Computational Drug Discovery Methods
article

A Fluorescence-Based Histidine-Imidazole Polyacrylamide Gel Electrophoresis (HI-PAGE) Method for Rapid and Practical Lipoprotein Profiling and LDL-C Quantification in Clinical Samples

Yasuhiro Takenaka, Masa‐Aki Ikeda, Yoshihiko Kakinuma, Ikuo Inoue
article en

Abstract

<b>Background</b>: Polyacrylamide gel electrophoresis (PAGE) has long been used for lipoprotein analysis, enabling the separation and profiling of lipoprotein fractions such as LDL and HDL. However, conventional disc PAGE systems are limited by low throughput and inability to directly compare multiple samples under identical conditions. Alternative methods, including high-performance liquid chromatography and agarose gel electrophoresis, require specialized equipment and expertise, limiting their clinical utility. <b>Methods</b>: We present a colorimetric and fluorescence-based histidine-imidazole PAGE (HI-PAGE) system that provides rapid, cost-effective, and reproducible separation and profiling of lipoproteins in human serum. By combining electrophoretic separation with lipid-specific fluorescent staining using Nile Red, the fluorescence-based HI-PAGE (fHI-PAGE) not only visualizes distinct migration patterns of lipoprotein fractions, but also enables the quantification of LDL-cholesterol (LDL-C). Clear resolution of LDL and other lipoprotein fractions was achieved within 1 h without band distortion, allowing for direct comparison of multiple samples on a single gel. <b>Results</b>: We validated fHI-PAGE using serum from healthy individuals and patients, demonstrating that its fluorescence-based detection was more sensitive than conventional Sudan Black B staining while providing LDL-C estimates concordant with values calculated by the Friedewald formula. Moreover, fHI-PAGE proved advantageous in cases of hypertriglyceridemia, where Friedewald calculations are unreliable. <b>Conclusions</b>: These findings establish fHI-PAGE as a practical and clinically applicable platform for simultaneous lipoprotein profiling and LDL-C quantification.

BiomedicinesVol. 13(10)
Nippon Medical School (JP), Saitama Medical University (JP)
Openalex Percentile: Top 68%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.