Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation

<b>Background:</b> Pulse oximetry is a non-invasive method for continuous monitoring of peripheral blood oxygen saturation (SpO<sub>2</sub>) to estimate arterial oxygen saturation. Previous studies suggested that SpO<sub>2</sub> measurements show variability depending on the particular finger that is used for measurement. To date, no study has compared all fingers for SpO<sub>2</sub> under hypoxemia and during continuous simultaneous monitoring with randomization of finger sensor placement. <b>Objectives</b>: The aim of this study was to assess the inter-finger variability of SpO<sub>2</sub> values during sequential desaturation and step resaturation. <b>Methods</b>: Forty-three out of forty-five healthy participants (age 23.0 ± 1.8 years, BMI 24.0 ± 4.4 kg·m<sup>-2</sup>) completed the experimental assessment with short-term induced hypoxemia by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). SpO<sub>2</sub> was measured continuously with the Masimo Radical-97 (Masimo Corp., Irvine, CA, USA) pulse oximeters. <b>Results</b>: The SpO<sub>2</sub> measured on the thumb was lower than all other fingers by 0.6% to 0.7% SpO<sub>2</sub>, a systematic difference that is less than the clinically accepted accuracy of oximeters. No difference in SpO<sub>2</sub> dynamics was found between any of the fingers during step resaturation. <b>Conclusions</b>: A systematic difference in measured SpO<sub>2</sub> exists between the thumb and the other fingers during desaturation, which should be considered at least as well as the impact of the performance of a particular oximeter, sensor placement or anatomical variability.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-10-21
DOI
https://doi.org/10.3390/healthcare13202648
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation

Petr Kudrna, Martin Rožánek, Jakub Ráfl, Šimon Walzel et al.
Healthcare
Non-Invasive Vital Sign Monitoring
article

Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation

Petr Kudrna, Martin Rožánek, Jakub Ráfl, Šimon Walzel, Marian Rybář, Veronika Rafl-Huttova
article en

Abstract

<b>Background:</b> Pulse oximetry is a non-invasive method for continuous monitoring of peripheral blood oxygen saturation (SpO<sub>2</sub>) to estimate arterial oxygen saturation. Previous studies suggested that SpO<sub>2</sub> measurements show variability depending on the particular finger that is used for measurement. To date, no study has compared all fingers for SpO<sub>2</sub> under hypoxemia and during continuous simultaneous monitoring with randomization of finger sensor placement. <b>Objectives</b>: The aim of this study was to assess the inter-finger variability of SpO<sub>2</sub> values during sequential desaturation and step resaturation. <b>Methods</b>: Forty-three out of forty-five healthy participants (age 23.0 ± 1.8 years, BMI 24.0 ± 4.4 kg·m<sup>-2</sup>) completed the experimental assessment with short-term induced hypoxemia by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). SpO<sub>2</sub> was measured continuously with the Masimo Radical-97 (Masimo Corp., Irvine, CA, USA) pulse oximeters. <b>Results</b>: The SpO<sub>2</sub> measured on the thumb was lower than all other fingers by 0.6% to 0.7% SpO<sub>2</sub>, a systematic difference that is less than the clinically accepted accuracy of oximeters. No difference in SpO<sub>2</sub> dynamics was found between any of the fingers during step resaturation. <b>Conclusions</b>: A systematic difference in measured SpO<sub>2</sub> exists between the thumb and the other fingers during desaturation, which should be considered at least as well as the impact of the performance of a particular oximeter, sensor placement or anatomical variability.

HealthcareVol. 13(20)
Czech Technical University in Prague (CZ)
Openalex Percentile: Top 71%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation — Petr Kudrna, Martin Rožánek, et al. · Healthcare (2025) | TGRS Research Map | TGRS