Investigation of Roadway Anti-Icing Without Auxiliary Heat Using Hydronic Heated Pavements Coupled with Borehole Thermal Energy Storage

Roadway anti-icing requires low-carbon alternatives to chloride salts and electric heating. This study evaluated a seasonal thermal energy storage system that couples a geothermal hydronic heated pavement (HHPS-G) with borehole thermal energy storage (BTES), operated without auxiliary heat. A coupled transient HHPS-G–BTES model was developed and validated against independent experimental data. A continuous cycle was then simulated, consisting of three months of summer pavement heat harvesting and BTES, followed by three months of winter heat discharge. A parametric analysis varied borehole depth (10, 20, and 40 m) and number of units (1, 2, and 4). Results indicated that depth is consistently more effective than unit number. Deeper fields produced larger summer pavement surface cooling with less long-term drift and yielded more persistent winter anti-icing performance. The 40 m 4-unit case lowered the end-of-summer surface temperature by 3.8 °C relative to the no-operation case and kept the surface at or above 0 °C throughout winter. In contrast, the 10 m–1-unit case was near 0 °C by late winter. A depth-first BTES design, supplemented by spacing or edge placement to limit interference, showed practical potential for anti-icing without auxiliary heat.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-10-21
DOI
https://doi.org/10.3390/en18205546
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Roadway Anti-Icing Without Auxiliary Heat Using Hydronic Heated Pavements Coupled with Borehole Thermal Energy Storage

Seokjae Lee, Abdolkarim Abbasi, Wansoo Ha, Sangwoo Park et al.
Energies
Smart Materials for Construction
article

Investigation of Roadway Anti-Icing Without Auxiliary Heat Using Hydronic Heated Pavements Coupled with Borehole Thermal Energy Storage

Seokjae Lee, Abdolkarim Abbasi, Wansoo Ha, Sangwoo Park, Hizb Ullah
article en

Abstract

Roadway anti-icing requires low-carbon alternatives to chloride salts and electric heating. This study evaluated a seasonal thermal energy storage system that couples a geothermal hydronic heated pavement (HHPS-G) with borehole thermal energy storage (BTES), operated without auxiliary heat. A coupled transient HHPS-G–BTES model was developed and validated against independent experimental data. A continuous cycle was then simulated, consisting of three months of summer pavement heat harvesting and BTES, followed by three months of winter heat discharge. A parametric analysis varied borehole depth (10, 20, and 40 m) and number of units (1, 2, and 4). Results indicated that depth is consistently more effective than unit number. Deeper fields produced larger summer pavement surface cooling with less long-term drift and yielded more persistent winter anti-icing performance. The 40 m 4-unit case lowered the end-of-summer surface temperature by 3.8 °C relative to the no-operation case and kept the surface at or above 0 °C throughout winter. In contrast, the 10 m–1-unit case was near 0 °C by late winter. A depth-first BTES design, supplemented by spacing or edge placement to limit interference, showed practical potential for anti-icing without auxiliary heat.

EnergiesVol. 18(20)
Kunsan National University (KR), Korea Military Academy (KR)
Openalex Percentile: Top 76%
Smart Materials for Construction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.