Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on <sup>18</sup> F-FDG PET/CT

Despite their clinical significance, the prevalence of bilateral low-accumulation bladder artifacts and the factors contributing to their occurrence in routine <sup>18</sup>F-FDG PET/CT examinations have not been comprehensively studied. The aim of this study was to determine the prevalence of bilateral low-accumulation bladder artifacts and identify factors associated with their occurrence in clinical <sup>18</sup>F-FDG PET/CT scans. <b>Methods:</b> Patients (<i>n</i> = 112) who underwent <sup>18</sup>F-FDG PET/CT for clinical purposes were retrospectively evaluated. PET images were reconstructed using 4 methods: 3-dimensional ordered-subset expectation maximization (OSEM) without time-of-flight (TOF); OSEM with TOF; Bayesian penalized likelihood (BPL) without TOF; and BPL with TOF. For non-TOF OSEM, PET images were reconstructed with and without scatter correction (SC). The SUV<sub>max</sub> in the bladder was compared in patients with and without bilateral low-accumulation bladder artifacts. Phantom experiments with 2 external shapes were conducted, and the relationship between the radioactivity (0, 20, 50, 120, and 280 kBq/mL) of the <sup>18</sup>F-FDG solution in the bladder-simulated sphere and the occurrence of the low-accumulation artifacts was evaluated. <b>Results:</b> The prevalence of bilateral bladder artifacts was significantly lower in PET images reconstructed with TOF OSEM (7 patients; 6.3%), non-TOF BPL (3 patients; 2.7%), and TOF BPL (0 patients) compared with non-TOF OSEM (39 patients; 34.8%) (<i>P</i> < 0.001). Artifacts were also observed on PET images without SC. The median bladder SUV<sub>max</sub> in patients with artifacts was significantly higher than that of patients without artifacts (59.8 vs. 28.5; <i>P</i> < 0.001). In phantom experiments using a rectangular model, bilateral bladder artifact intensity increased as the radioactivity in the simulated bladder increased on non-TOF reconstructions with and without SC. No artifacts were observed in experiments using a spheric phantom. <b>Conclusion:</b> Bilateral low-accumulation bladder artifacts were observed in approximately 35% of clinical <sup>18</sup>F-FDG PET/CT images reconstructed with non-TOF OSEM. Artifact occurrence was associated with radioactivity in the urinary bladder, independent of SC, and influenced by body shape. TOF and BPL reconstructions reduced artifact prevalence.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2025-10-21
DOI
https://doi.org/10.2967/jnmt.125.270294
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT

Yasutaka Ichikawa, Yoya Tomita, Hajime Sakuma, Kengo Hashizume
Journal of Nuclear Medicine Technology
Medical Imaging Techniques and Applications
article

Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT

Yasutaka Ichikawa, Yoya Tomita, Hajime Sakuma, Kengo Hashizume
article en

Abstract

Despite their clinical significance, the prevalence of bilateral low-accumulation bladder artifacts and the factors contributing to their occurrence in routine <sup>18</sup>F-FDG PET/CT examinations have not been comprehensively studied. The aim of this study was to determine the prevalence of bilateral low-accumulation bladder artifacts and identify factors associated with their occurrence in clinical <sup>18</sup>F-FDG PET/CT scans. <b>Methods:</b> Patients (<i>n</i> = 112) who underwent <sup>18</sup>F-FDG PET/CT for clinical purposes were retrospectively evaluated. PET images were reconstructed using 4 methods: 3-dimensional ordered-subset expectation maximization (OSEM) without time-of-flight (TOF); OSEM with TOF; Bayesian penalized likelihood (BPL) without TOF; and BPL with TOF. For non-TOF OSEM, PET images were reconstructed with and without scatter correction (SC). The SUV<sub>max</sub> in the bladder was compared in patients with and without bilateral low-accumulation bladder artifacts. Phantom experiments with 2 external shapes were conducted, and the relationship between the radioactivity (0, 20, 50, 120, and 280 kBq/mL) of the <sup>18</sup>F-FDG solution in the bladder-simulated sphere and the occurrence of the low-accumulation artifacts was evaluated. <b>Results:</b> The prevalence of bilateral bladder artifacts was significantly lower in PET images reconstructed with TOF OSEM (7 patients; 6.3%), non-TOF BPL (3 patients; 2.7%), and TOF BPL (0 patients) compared with non-TOF OSEM (39 patients; 34.8%) (<i>P</i> < 0.001). Artifacts were also observed on PET images without SC. The median bladder SUV<sub>max</sub> in patients with artifacts was significantly higher than that of patients without artifacts (59.8 vs. 28.5; <i>P</i> < 0.001). In phantom experiments using a rectangular model, bilateral bladder artifact intensity increased as the radioactivity in the simulated bladder increased on non-TOF reconstructions with and without SC. No artifacts were observed in experiments using a spheric phantom. <b>Conclusion:</b> Bilateral low-accumulation bladder artifacts were observed in approximately 35% of clinical <sup>18</sup>F-FDG PET/CT images reconstructed with non-TOF OSEM. Artifact occurrence was associated with radioactivity in the urinary bladder, independent of SC, and influenced by body shape. TOF and BPL reconstructions reduced artifact prevalence.

Journal of Nuclear Medicine TechnologyVol. 54(1)
Mie University Hospital (JP)
Openalex Percentile: Top 56%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.