Achromatic laboratory full-field transmission X-ray microscope

The implementation of full-field transmission X-ray microscopy (TXM) at X-ray tube sources suffers from image blurring due to the chromatic aberration of the lenses and from long exposure times due to the inherent low flux of laboratory sources. Here, we demonstrate the first laboratory full-field TXM system, which combines tailored monocapillary optics, an achromatic X-ray lens, and the MÖNCH hybrid silicon pixel detector to address these challenges. With current optics, this TXM system demonstrates a spatial resolution down to 480 nm using X-ray energies around 10 keV. Despite the large pixel pitch of the MÖNCH detector, high spatial resolution imaging can be achieved by using interpolation methods leveraging charge sharing. In addition, the energy resolving power of the MÖNCH detector allows for the acquisition of elemental information. Bridging the gap between structural and elemental characterizations using X-rays, the concept of this laboratory X-ray microscope provides new opportunities for research in the fields of material science, environmental science, and biology.

Authors

Institutions

Publication Details

Journal
Photonics Research
Published
2025-10-21
DOI
https://doi.org/10.1364/prj.573807
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achromatic laboratory full-field transmission X-ray microscope

Di Qu, Julian Heymes, Christian Dávid, Shuai Zhao et al.
Photonics Research
Advanced X-ray Imaging Techniques
article

Achromatic laboratory full-field transmission X-ray microscope

Di Qu, Julian Heymes, Christian Dávid, Shuai Zhao, Peng Qi, A. Bergamaschi, Joan Vila‐Comamala, R. Dinapoli, Mano raj Dhanalakshmi veeraraj
article en

Abstract

The implementation of full-field transmission X-ray microscopy (TXM) at X-ray tube sources suffers from image blurring due to the chromatic aberration of the lenses and from long exposure times due to the inherent low flux of laboratory sources. Here, we demonstrate the first laboratory full-field TXM system, which combines tailored monocapillary optics, an achromatic X-ray lens, and the MÖNCH hybrid silicon pixel detector to address these challenges. With current optics, this TXM system demonstrates a spatial resolution down to 480 nm using X-ray energies around 10 keV. Despite the large pixel pitch of the MÖNCH detector, high spatial resolution imaging can be achieved by using interpolation methods leveraging charge sharing. In addition, the energy resolving power of the MÖNCH detector allows for the acquisition of elemental information. Bridging the gap between structural and elemental characterizations using X-rays, the concept of this laboratory X-ray microscope provides new opportunities for research in the fields of material science, environmental science, and biology.

Photonics ResearchVol. 14(2)
University of Science and Technology of China (CN), Paul Scherrer Institute (CH)
Openalex Percentile: Top 60%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.