Inconsistent Pulse Oximetry Signal in Multiple Sites as an Early Indicator of Severe Hypovolemia

A low-quality pulse oximetry signal should not be overlooked, as this may indicate cases of severe hypovolemia. Although this sign is not specific for volume depletion, it can provide a quick, non-invasive indication about possible hypovolemia if a proper signal cannot be obtained, especially when difficulties are encountered in obtaining SpO<sub>2</sub> readings from multiple sites. Severe hypovolemia is a preventable risk factor for shock and other electrolyte abnormalities, which, if untreated, may lead to cardiovascular collapse or even necessitate cardiopulmonary resuscitation (CPR). This case report highlights the potential usefulness of a pulse oximeter's poor signal in multiple sites in helping providers detect volume depletion in the perioperative setting, which could prevent avoidable causes of acute decompensation during anesthetic induction.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-21
DOI
https://doi.org/10.7759/cureus.95085
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inconsistent Pulse Oximetry Signal in Multiple Sites as an Early Indicator of Severe Hypovolemia

William T. Davis, Richard Malík, Mohamad Taha, Sharif Mohamed
Cureus
Hemodynamic Monitoring and Therapy
article

Inconsistent Pulse Oximetry Signal in Multiple Sites as an Early Indicator of Severe Hypovolemia

William T. Davis, Richard Malík, Mohamad Taha, Sharif Mohamed
article en

Abstract

A low-quality pulse oximetry signal should not be overlooked, as this may indicate cases of severe hypovolemia. Although this sign is not specific for volume depletion, it can provide a quick, non-invasive indication about possible hypovolemia if a proper signal cannot be obtained, especially when difficulties are encountered in obtaining SpO<sub>2</sub> readings from multiple sites. Severe hypovolemia is a preventable risk factor for shock and other electrolyte abnormalities, which, if untreated, may lead to cardiovascular collapse or even necessitate cardiopulmonary resuscitation (CPR). This case report highlights the potential usefulness of a pulse oximeter's poor signal in multiple sites in helping providers detect volume depletion in the perioperative setting, which could prevent avoidable causes of acute decompensation during anesthetic induction.

CureusVol. 17(10)
The University of Texas Medical Branch at Galveston (US)
Openalex Percentile: Top 53%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.