Evaluating the accuracy of acoustic holograms for precise spatial targeting within the brain

Acoustic holography can reconstruct desired pressure fields and overcome phase aberrations caused by refractions in heterogeneous media, such as the skull. However, the accuracy of holographic targeting within the brain has not yet been thoroughly evaluated. We sought to characterize the holographic focusing limits for focused and unfocused single-element transducers. Holographic lenses enlarged the focal size by more than 4-fold. Bifocal lenses achieved foci separation of 7-68 mm and focal depths of 7-83 mm. Lenses were tested in silico and in free-field experiments, with RMS errors of 0.03-0.33. Focused transducers were preferable at low F numbers and were better-suited for murine brain targeting. However, planar transducers can focus over larger areas so have higher clinical relevance in the human brain. Finally, simulations with a human skull showed an RMS error < 0.01. This work provides valuable insight into the accuracy of acoustic holography, demonstrating that transducer design is essential for clinical brain applications.

Authors

Institutions

Publication Details

Journal
npj Acoustics
Published
2025-10-21
DOI
https://doi.org/10.1038/s44384-025-00031-8
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the accuracy of acoustic holograms for precise spatial targeting within the brain

Antonios N. Pouliopoulos, Rachel Burstow
npj Acoustics
Photoacoustic and Ultrasonic Imaging
article

Evaluating the accuracy of acoustic holograms for precise spatial targeting within the brain

Antonios N. Pouliopoulos, Rachel Burstow
article en

Abstract

Acoustic holography can reconstruct desired pressure fields and overcome phase aberrations caused by refractions in heterogeneous media, such as the skull. However, the accuracy of holographic targeting within the brain has not yet been thoroughly evaluated. We sought to characterize the holographic focusing limits for focused and unfocused single-element transducers. Holographic lenses enlarged the focal size by more than 4-fold. Bifocal lenses achieved foci separation of 7-68 mm and focal depths of 7-83 mm. Lenses were tested in silico and in free-field experiments, with RMS errors of 0.03-0.33. Focused transducers were preferable at low F numbers and were better-suited for murine brain targeting. However, planar transducers can focus over larger areas so have higher clinical relevance in the human brain. Finally, simulations with a human skull showed an RMS error < 0.01. This work provides valuable insight into the accuracy of acoustic holography, demonstrating that transducer design is essential for clinical brain applications.

npj AcousticsVol. 1(1)
King's College London (GB)
Focused Ultrasound Foundation, Children's Cancer and Leukaemia Group, LifeArc, Action Medical Research, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 71%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.