Development of a Table-Top NRTA System: Monte Carlo Study of Collimator/Shielding for Pu Pellet Sample Measurement

The present Monte Carlo study was conducted to evaluate the efficacy of a table-top Neutron Resonance Transmission Analysis (NRTA) system for measuring small Nuclear Material (NM) samples, such as plutonium (Pu) pellets, using a compact 252 Cf spontaneous fission neutron source.Time-of-flight spectra obtained from a 2 cm cylindrical Pu pellet sample exhibited resonance dips when subjected to collimator/shielding made of polyethylene (PE) that contained 20 % of BO (BO-PE) and 50 % of LiF (LiF-PE).In contrast, the TOF spectra obtained using plain PE and air exhibited no discernible resonance dips.These results demonstrate the capability of the designed table-top NRTA system to measure small NM samples efficiently when employing suitable collimator/shielding materials.Given the results associated with BO-PE, it is planned to be used in implementing the physical table-top NRTA system.

Authors

Institutions

Publication Details

Journal
Progress in Nuclear Science and Technology
Published
2025-09-30
DOI
https://doi.org/10.15669/pnst.8.377
Citations
3
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
5.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Table-Top NRTA System: Monte Carlo Study of Collimator/Shielding for Pu Pellet Sample Measurement

H. Tsuchiya, Cébastien Joël Guembou Shouop
3 citations
Progress in Nuclear Science and Technology
Nuclear Physics and Applications
5.65
article

Development of a Table-Top NRTA System: Monte Carlo Study of Collimator/Shielding for Pu Pellet Sample Measurement

H. Tsuchiya, Cébastien Joël Guembou Shouop
article en
3 citations

Abstract

The present Monte Carlo study was conducted to evaluate the efficacy of a table-top Neutron Resonance Transmission Analysis (NRTA) system for measuring small Nuclear Material (NM) samples, such as plutonium (Pu) pellets, using a compact 252 Cf spontaneous fission neutron source.Time-of-flight spectra obtained from a 2 cm cylindrical Pu pellet sample exhibited resonance dips when subjected to collimator/shielding made of polyethylene (PE) that contained 20 % of BO (BO-PE) and 50 % of LiF (LiF-PE).In contrast, the TOF spectra obtained using plain PE and air exhibited no discernible resonance dips.These results demonstrate the capability of the designed table-top NRTA system to measure small NM samples efficiently when employing suitable collimator/shielding materials.Given the results associated with BO-PE, it is planned to be used in implementing the physical table-top NRTA system.

Progress in Nuclear Science and TechnologyVol. 8(0)
Japan Atomic Energy Agency (JP)
Ministry of Education, Culture, Sports, Science and Technology, Japan Atomic Energy Agency
Openalex Percentile: Top 3%
Nuclear Physics and Applications
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.