First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

<i>Objective.</i>Achieving a higher signal-to-noise ratio gain or direct positron emission imaging by improving the coincidence time resolution of time-of-flight positron emission tomography (PET) systems is paramount for many advanced clinical PET imaging applications. This places greater demands on the timing performance of all PET system components.<i>Approach.</i>An effective method for enhancing detector time resolution is to use microchannel plate photomultiplier tubes (MCP-PMTs) for prompt Cherenkov photon detection. In this study, we developed a dual-module PET imaging experimental platform. This platform uses two 8 × 8-anode Cherenkov radiator-integrated window MCP-PMTs, which was developed in-house. It also uses multi-channel electronics system, which was also developed in-house. We designed specific calibration and correction methods for the platform to meet the experimental requirements.<i>Main results.</i>Based on this dual-module platform, a total Full Width at half maximum of 203.6 ps (<i>σ</i>= 86.5 ps) was achieved. Multi-component analysis of the time spectrum was performed based on the interaction positions of annihilation photon pairs in different coincidence events. Imaging experiments were conducted using various types of radiation sources and phantoms. Spatial resolution was evaluated, confirming the platform's ability to distinguish 4 mm spots in Derenzo-like phantoms. Furthermore, preliminary improvements in image quality were verified when incorporating TOF information into the dual-module platform.<i>Significance.</i>In this study, we achieved the first experimental verification of module-level PET imaging based on the detection of Cherenkov light. This has overcome the limitations of single-pixel detectors in previous related research and reduced the radiation dose and acquisition time required for imaging by nearly 10 times. Additionally, this study evaluated the potential of a dual-module platform for achieving higher temporal performance and direct imaging, elucidated the importance of developing PbF<sub>2</sub>integrated window multi-anode MCP-PMTs, and provided experimental evidence for future performance enhancements in Cherenkov light detection-based PET systems.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-10-21
DOI
https://doi.org/10.1088/1361-6560/ae15e3
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

S. Qian, Jun Hu, Weiyan Pan, Xiaorou Han et al.
1 citations
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
1.36
article

First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

S. Qian, Jun Hu, Weiyan Pan, Xiaorou Han, J. Ye, Zehong Liang, Xianchao Huang, Guorui Huang, Xiongbo Yan, Y. F. Wang, Yangfu Wang, Ling Ren, Qing Wei, Daowu Li, Xin Wang, Wei Hou, Zhiming Zhang, Yingjie Wang, Zhi Wang, Ning Wang, Jingwen Li, Tianyi Wang, Long Wei, Hang Yuan, Xingchao Wang, Qi Wu, Shuguang Si, Meiling Zhu, Lingyue Chen, Lishuang Ma, Jianning Sun, Zhe Ning, Yunhua Sun, Xiaoshan Jiang, Zhen Jin, Shulin Liu
article en
1 citations

Abstract

<i>Objective.</i>Achieving a higher signal-to-noise ratio gain or direct positron emission imaging by improving the coincidence time resolution of time-of-flight positron emission tomography (PET) systems is paramount for many advanced clinical PET imaging applications. This places greater demands on the timing performance of all PET system components.<i>Approach.</i>An effective method for enhancing detector time resolution is to use microchannel plate photomultiplier tubes (MCP-PMTs) for prompt Cherenkov photon detection. In this study, we developed a dual-module PET imaging experimental platform. This platform uses two 8 × 8-anode Cherenkov radiator-integrated window MCP-PMTs, which was developed in-house. It also uses multi-channel electronics system, which was also developed in-house. We designed specific calibration and correction methods for the platform to meet the experimental requirements.<i>Main results.</i>Based on this dual-module platform, a total Full Width at half maximum of 203.6 ps (<i>σ</i>= 86.5 ps) was achieved. Multi-component analysis of the time spectrum was performed based on the interaction positions of annihilation photon pairs in different coincidence events. Imaging experiments were conducted using various types of radiation sources and phantoms. Spatial resolution was evaluated, confirming the platform's ability to distinguish 4 mm spots in Derenzo-like phantoms. Furthermore, preliminary improvements in image quality were verified when incorporating TOF information into the dual-module platform.<i>Significance.</i>In this study, we achieved the first experimental verification of module-level PET imaging based on the detection of Cherenkov light. This has overcome the limitations of single-pixel detectors in previous related research and reduced the radiation dose and acquisition time required for imaging by nearly 10 times. Additionally, this study evaluated the potential of a dual-module platform for achieving higher temporal performance and direct imaging, elucidated the importance of developing PbF<sub>2</sub>integrated window multi-anode MCP-PMTs, and provided experimental evidence for future performance enhancements in Cherenkov light detection-based PET systems.

Physics in Medicine and BiologyVol. 70(22)
Chinese Academy of Sciences (CN), Nanjing Institute of Technology (CN), University of Jinan (CN), Technology Applications (United States) (US), Beijing Shijingshan Hospital (CN), Institute of High Energy Physics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 15%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.