Optimal control of ventilation in enclosed spaces using Adversarial Neural Networks

Systems that manage and control air quality are the main energy consumers within a building and their design often relies on assumptions that lead to excessive energy usage. This paper proposes a new method based on Computational Fluid Dynamics (CFD) and Artificial Intelligence (AI) that can assimilate observations and control ventilation systems to achieve a certain goal, such as maintaining a particular temperature range in an indoor environment. An AI-based reduced-order model (ROM) is used here because current CFD methods generally have too large a computational expense for real-time control. We use proper orthogonal decomposition (POD) to represent the spatial distributions of the CFD simulations and learn the evolution of the POD coefficients in time with an Adversarial Neural Network. With this AI-based ROM, we can perform 4D Variational Data Assimilation (4D-Var DA) and control with a rapid workflow that incorporates the spatial variation of all the key variables: air flow velocity, CO 2 , temperature, relative humidity and viral load. The proposed method is applied to three scenarios: (i) a ventilation scenario in which the aim is to keep the occupants healthy (indicated by ventilation and CO 2 levels) as well as thermally comfortable while minimising energy consumption; (ii) a pandemic scenario in which the priority is to keep people infection-free; (iii) a compromise between (i) and (ii). These three scenarios are developed within a classroom containing 26 children and one teacher, and are combined with an extensive set of measurement data, collected in the classroom of a primary school located in London. Our method successfully met the control objectives in all three scenarios. • We present a novel reduced-order model (ROM) for control and data assimilation. • The ROM uses an adversarial autoencoder (AAE) for prediction in time. • A new 4D variational data assimilation method is presented. • Observations are included in the AAE’s input and output, providing great flexibility. • The ROM is applied to a classroom with observations of CO 2 , humidity and temperature.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-10-21
DOI
https://doi.org/10.1016/j.buildenv.2025.113858
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal control of ventilation in enclosed spaces using Adversarial Neural Networks

Donghu Guo, Christopher C. Pain, Claire E. Heaney, Jieyi Tang et al.
Building and Environment
Infection Control and Ventilation
article

Optimal control of ventilation in enclosed spaces using Adversarial Neural Networks

Donghu Guo, Christopher C. Pain, Claire E. Heaney, Jieyi Tang, Andrea Cammarano, Boyang Chen, Prashant Kumar
article en

Abstract

Systems that manage and control air quality are the main energy consumers within a building and their design often relies on assumptions that lead to excessive energy usage. This paper proposes a new method based on Computational Fluid Dynamics (CFD) and Artificial Intelligence (AI) that can assimilate observations and control ventilation systems to achieve a certain goal, such as maintaining a particular temperature range in an indoor environment. An AI-based reduced-order model (ROM) is used here because current CFD methods generally have too large a computational expense for real-time control. We use proper orthogonal decomposition (POD) to represent the spatial distributions of the CFD simulations and learn the evolution of the POD coefficients in time with an Adversarial Neural Network. With this AI-based ROM, we can perform 4D Variational Data Assimilation (4D-Var DA) and control with a rapid workflow that incorporates the spatial variation of all the key variables: air flow velocity, CO 2 , temperature, relative humidity and viral load. The proposed method is applied to three scenarios: (i) a ventilation scenario in which the aim is to keep the occupants healthy (indicated by ventilation and CO 2 levels) as well as thermally comfortable while minimising energy consumption; (ii) a pandemic scenario in which the priority is to keep people infection-free; (iii) a compromise between (i) and (ii). These three scenarios are developed within a classroom containing 26 children and one teacher, and are combined with an extensive set of measurement data, collected in the classroom of a primary school located in London. Our method successfully met the control objectives in all three scenarios. • We present a novel reduced-order model (ROM) for control and data assimilation. • The ROM uses an adversarial autoencoder (AAE) for prediction in time. • A new 4D variational data assimilation method is presented. • Observations are included in the AAE’s input and output, providing great flexibility. • The ROM is applied to a classroom with observations of CO 2 , humidity and temperature.

Building and EnvironmentVol. 287
University of Surrey (GB), University of Southampton (GB), Imperial College London (GB), University of Glasgow (GB)
Openalex Percentile: Top 57%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.