Enhancing Photoelectrochemical Oxygen Demand Detection by Superhydrophobic and Surface‐Passivated Cocatalyst Engineering

Photoelectrochemical oxygen demand (PeCOD) technology has attracted significant attention in water quality monitoring due to its advantages of rapid analysis and avoidance of highly toxic reagents. However, the increasing diversity of water pollutants (including biomass derivatives, petroleum byproducts, and plastics byproducts) poses a new challenge to the broad-spectrum detection capability of photoanodes. Herein, calcination transformed the BiVO<sub>4</sub> photoanode modified with polytrithiophene (pTTh) and NiOOH cocatalysts, yielding a superhydrophobic BiVO<sub>4</sub> photoanode with amorphous nickel oxide (NiO<sub>x</sub>) and sulfur-incorporated carbon cocatalysts (NiO<sub>x</sub>/SC). The NiO<sub>x</sub>/SC/BiVO<sub>4</sub> photoanode not only has higher photovoltage through surface defect passivation, but also enhances the selectivity for organic oxidation reactions by suppressing competitive water splitting. The NiO<sub>x</sub>/SC/BiVO<sub>4</sub> photoanode shows excellent detection performance in biomass, petroleum byproducts and plastic byproducts represented by glucose, glycerol, and ethylene glycol, with a linear detection range of 192-19200 ppm (R<sup>2</sup> = 0.9953) and a detection limit of 1 mm (S/N = 14). The synergistic effect of the surface defect passivation and the hydrophobic modification provides an efficient and stable solution for broad-spectrum pollutant detection. This study not only provides material design strategies for the practical application of the PeCOD detection sensor, but also establishes a novel approach for rapid monitoring of complex aqueous systems.

Authors

Institutions

Publication Details

Journal
ChemSusChem
Published
2025-10-20
DOI
https://doi.org/10.1002/cssc.202501758
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Photoelectrochemical Oxygen Demand Detection by Superhydrophobic and Surface‐Passivated Cocatalyst Engineering

Changping Huang, Jieyu Li, Kai‐Hang Ye, Chunsong Xie et al.
ChemSusChem
Water Quality Monitoring and Analysis
article

Enhancing Photoelectrochemical Oxygen Demand Detection by Superhydrophobic and Surface‐Passivated Cocatalyst Engineering

Changping Huang, Jieyu Li, Kai‐Hang Ye, Chunsong Xie, Wenhao Zou, Sun‐Mou Lai, Haibo Shao, Haiyan Xie, Xiaoxin Chen, Xiaoqi Chen, Changyu Liu, Sitong Ge, Shanqing Zhang, Yushen Xiao, Junwei Chen
article en

Abstract

Photoelectrochemical oxygen demand (PeCOD) technology has attracted significant attention in water quality monitoring due to its advantages of rapid analysis and avoidance of highly toxic reagents. However, the increasing diversity of water pollutants (including biomass derivatives, petroleum byproducts, and plastics byproducts) poses a new challenge to the broad-spectrum detection capability of photoanodes. Herein, calcination transformed the BiVO<sub>4</sub> photoanode modified with polytrithiophene (pTTh) and NiOOH cocatalysts, yielding a superhydrophobic BiVO<sub>4</sub> photoanode with amorphous nickel oxide (NiO<sub>x</sub>) and sulfur-incorporated carbon cocatalysts (NiO<sub>x</sub>/SC). The NiO<sub>x</sub>/SC/BiVO<sub>4</sub> photoanode not only has higher photovoltage through surface defect passivation, but also enhances the selectivity for organic oxidation reactions by suppressing competitive water splitting. The NiO<sub>x</sub>/SC/BiVO<sub>4</sub> photoanode shows excellent detection performance in biomass, petroleum byproducts and plastic byproducts represented by glucose, glycerol, and ethylene glycol, with a linear detection range of 192-19200 ppm (R<sup>2</sup> = 0.9953) and a detection limit of 1 mm (S/N = 14). The synergistic effect of the surface defect passivation and the hydrophobic modification provides an efficient and stable solution for broad-spectrum pollutant detection. This study not only provides material design strategies for the practical application of the PeCOD detection sensor, but also establishes a novel approach for rapid monitoring of complex aqueous systems.

ChemSusChemVol. 18(22)
Guangdong University of Technology (CN), Ji Hua Laboratory (CN), Wuyi University (CN), Beijing Chaoyang Emergency Medical Center (CN), Huizhou University (CN)
Openalex Percentile: Top 63%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.