Nanoindentation under retrocorneal pressure to determine the biomechanical response of the human cornea to accelerated UVA crosslinking and riboflavin osmolarity ex vivo

Riboflavin-mediated UVA corneal crosslinking (CXL) is an established treatment to halt the progression of keratoconus. However, the biomechanical effects of accelerated protocols and varying riboflavin osmolarities under physiological conditions remain poorly understood. Traditional biomechanical assessments using nanoindentation typically analyze tissue flatmounts, disregarding the natural tissue strain exerted by intraocular pressure. We developed a novel experimental setup combining nanoindentation with adjustable retrocorneal fluid pressure (RCP) to simulate physiological conditions during measurements. Using this approach, we first examined five corneas under incrementally increasing RCP levels to quantify the effect of tissue pre-tension on biomechanical properties. In a subsequent series, we investigated 70 human corneas to evaluate seven different protocols, including accelerated treatment protocols and different riboflavin osmolarities, by analyzing the Hertz-elastic modulus (E<sub>HZ</sub>) and creep behavior (C<sub>IT</sub>). Our results demonstrate that all CXL protocols significantly enhanced corneal stiffness and reduced tissue creep. Compared to the standard Dresden protocol, the biomechanical effect was enhanced with hyperosmolar riboflavin but diminished when high radiation intensity was used for shorter duration. Furthermore, increasing RCP led to non-linear changes in corneal biomechanics, manifesting as increased E<sub>HZ</sub> and decreased C<sub>IT</sub>. These findings emphasize the importance of considering physiological tissue pre-tension in biomechanical assessments and provide new insights for optimizing CXL treatment protocols.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-21
DOI
https://doi.org/10.1038/s41598-025-24522-6
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanoindentation under retrocorneal pressure to determine the biomechanical response of the human cornea to accelerated UVA crosslinking and riboflavin osmolarity ex vivo

Robert Lohmüller, Günther Schlunck, Thomas Reinhard, Daniel Böhringer et al.
Scientific Reports
Corneal surgery and disorders
article

Nanoindentation under retrocorneal pressure to determine the biomechanical response of the human cornea to accelerated UVA crosslinking and riboflavin osmolarity ex vivo

Robert Lohmüller, Günther Schlunck, Thomas Reinhard, Daniel Böhringer, Stefan J. Lang, Bero Bressler
article en

Abstract

Riboflavin-mediated UVA corneal crosslinking (CXL) is an established treatment to halt the progression of keratoconus. However, the biomechanical effects of accelerated protocols and varying riboflavin osmolarities under physiological conditions remain poorly understood. Traditional biomechanical assessments using nanoindentation typically analyze tissue flatmounts, disregarding the natural tissue strain exerted by intraocular pressure. We developed a novel experimental setup combining nanoindentation with adjustable retrocorneal fluid pressure (RCP) to simulate physiological conditions during measurements. Using this approach, we first examined five corneas under incrementally increasing RCP levels to quantify the effect of tissue pre-tension on biomechanical properties. In a subsequent series, we investigated 70 human corneas to evaluate seven different protocols, including accelerated treatment protocols and different riboflavin osmolarities, by analyzing the Hertz-elastic modulus (E<sub>HZ</sub>) and creep behavior (C<sub>IT</sub>). Our results demonstrate that all CXL protocols significantly enhanced corneal stiffness and reduced tissue creep. Compared to the standard Dresden protocol, the biomechanical effect was enhanced with hyperosmolar riboflavin but diminished when high radiation intensity was used for shorter duration. Furthermore, increasing RCP led to non-linear changes in corneal biomechanics, manifesting as increased E<sub>HZ</sub> and decreased C<sub>IT</sub>. These findings emphasize the importance of considering physiological tissue pre-tension in biomechanical assessments and provide new insights for optimizing CXL treatment protocols.

Scientific ReportsVol. 15(1)
University of Freiburg (DE), University Medical Center Freiburg (DE), Universitätsklinikum Brandenburg an der Havel (DE)
Deutsche Forschungsgemeinschaft, Albert-Ludwigs-Universität Freiburg
Openalex Percentile: Top 56%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.