Two-Dimensional FAIMS-TIMS Separation for Probing Structural Diversity of Peptides with Resolution Exceeding 6500

A two-dimensional gas-phase ion separation platform was developed by coupling high-sensitivity and high-resolution racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) with trapped ion mobility spectrometry (TIMS) and time-of-flight mass spectrometry. This platform was applied to explore the conformational diversity of doubly charged bradykinin (BK+2H<sup>+</sup>)<sup>2+</sup> ions. Four conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion can be resolved by using fully optimized TIMS, while six conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion with different compensation voltages (CV) can be resolved by using r-FAIMS with pure nitrogen as a carrier gas and a 2.6 kV dispersion voltage (DV). By further TIMS analyses of the CV-selected (BK+2H<sup>+</sup>)<sup>2+</sup> ions corresponding to all the six FAIMS separated peaks, nearly 30 conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion can be resolved. Multiple conformers of (BK+2H<sup>+</sup>)<sup>2+</sup> ions were found to have completely different CV values, although their mobilities were essentially the same. Multiple TIMS peaks, which are basically buried in the ambient noise in the normal TIMS spectrum, can be easily detected in the CV-selected TIMS spectra. These experimental measurements have positively proven that the separations in the FAIMS and TIMS dimensions are highly orthogonal. The overall resolving power of two-dimensional r-FAIMS-TIMS separation is essentially proportional to the product of the resolving powers of r-FAIMS and TIMS. The theoretical calculation, based on the data correlation between FAIMS and TIMS measurements, has shown that the total resolving power of the combined r-FAIMS and TIMS separation exceeds 6500 for the (BK+2H<sup>+</sup>)<sup>2+</sup> ions, making the new instrument platform very effective for the structural elucidation of large biomolecules.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-21
DOI
https://doi.org/10.1021/acs.analchem.5c05173
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Dimensional FAIMS-TIMS Separation for Probing Structural Diversity of Peptides with Resolution Exceeding 6500

Zhonghan Hu, Keqi Tang, Chenlu Wang, Rong Liu et al.
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

Two-Dimensional FAIMS-TIMS Separation for Probing Structural Diversity of Peptides with Resolution Exceeding 6500

Zhonghan Hu, Keqi Tang, Chenlu Wang, Rong Liu, Jiancheng Yu, Y.Q. Lei, Junhui Li, Yong Wu, Xixuan Gu, Kuang Jen Wu
article en

Abstract

A two-dimensional gas-phase ion separation platform was developed by coupling high-sensitivity and high-resolution racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) with trapped ion mobility spectrometry (TIMS) and time-of-flight mass spectrometry. This platform was applied to explore the conformational diversity of doubly charged bradykinin (BK+2H<sup>+</sup>)<sup>2+</sup> ions. Four conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion can be resolved by using fully optimized TIMS, while six conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion with different compensation voltages (CV) can be resolved by using r-FAIMS with pure nitrogen as a carrier gas and a 2.6 kV dispersion voltage (DV). By further TIMS analyses of the CV-selected (BK+2H<sup>+</sup>)<sup>2+</sup> ions corresponding to all the six FAIMS separated peaks, nearly 30 conformers of the (BK+2H<sup>+</sup>)<sup>2+</sup> ion can be resolved. Multiple conformers of (BK+2H<sup>+</sup>)<sup>2+</sup> ions were found to have completely different CV values, although their mobilities were essentially the same. Multiple TIMS peaks, which are basically buried in the ambient noise in the normal TIMS spectrum, can be easily detected in the CV-selected TIMS spectra. These experimental measurements have positively proven that the separations in the FAIMS and TIMS dimensions are highly orthogonal. The overall resolving power of two-dimensional r-FAIMS-TIMS separation is essentially proportional to the product of the resolving powers of r-FAIMS and TIMS. The theoretical calculation, based on the data correlation between FAIMS and TIMS measurements, has shown that the total resolving power of the combined r-FAIMS and TIMS separation exceeds 6500 for the (BK+2H<sup>+</sup>)<sup>2+</sup> ions, making the new instrument platform very effective for the structural elucidation of large biomolecules.

Analytical ChemistryVol. 97(43)
Ningbo University (CN), IONICS Mass Spectrometry (Canada) (CA)
Openalex Percentile: Top 72%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.