Charging stations demand forecasting using LSTM based hybrid transformer model

Accurate forecasting of energy demand for electric vehicles (EVs) is crucial for maintaining the stability and reliability of power systems. By predicting demand over various periods, charging station owners can ensure a continuous energy supply. Medium-term and long-term demand predictions, which extend from a few weeks to several days, help analyze charging demand across different periods based on historical trends. This study proposes a Transformer model that utilizes an LSTM-based encoder-decoder for forecasting the demand at electric vehicle charging stations (EVCS). The proposed model is compared with traditional deep learning-based LSTM and Transformer models. The research employs open datasets from ACN, including charging data from Caltech and JPL. Both datasets are used to train and test the models. Predictions are made for 30 days, 120 days, and 240 days ahead, with results compared to actual demand. Performance is evaluated using Mean Absolute Error (MAE) and Mean Squared Error (MSE). Compared to baseline models, the proposed LSTM-Transformer model for Caltech data shows a significant improvement at the 30-day horizon, lowering MAE by up to 17.27% and MSE by 19.79%. The accuracy improvement are minor but consistent in longer horizons (120 and 240 days), with an MAE and MSE improvement of up to 5.71% and 4.85%, respectively. The LSTM-Transformer model also shows better accuracy across all horizons for JPL data by reducing MAE and MSE by up to 24.91% and 23.17% at 30 days, 5.00% and 5.17% at 120 days, and 3.90% and 4.86% at 240 days. The results indicate that the Hybrid Transformer model outperforms the baseline models for both datasets in medium-term and long-term predictions. The 30, 120, and 240-day predictions demonstrate lower error rates with the proposed model when utilizing Caltech and JPL charging data for these time frames.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-21
DOI
https://doi.org/10.1038/s41598-025-20421-y
Citations
1
Primary Topic
Energy Load and Power Forecasting
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Charging stations demand forecasting using LSTM based hybrid transformer model

Sajib Tripura, Ayesha Aslam, Adil Hussain, Vishwanath Eswarakrishnan
1 citations
Scientific Reports
Energy Load and Power Forecasting
0.73
article

Charging stations demand forecasting using LSTM based hybrid transformer model

Sajib Tripura, Ayesha Aslam, Adil Hussain, Vishwanath Eswarakrishnan
article en
1 citations

Abstract

Accurate forecasting of energy demand for electric vehicles (EVs) is crucial for maintaining the stability and reliability of power systems. By predicting demand over various periods, charging station owners can ensure a continuous energy supply. Medium-term and long-term demand predictions, which extend from a few weeks to several days, help analyze charging demand across different periods based on historical trends. This study proposes a Transformer model that utilizes an LSTM-based encoder-decoder for forecasting the demand at electric vehicle charging stations (EVCS). The proposed model is compared with traditional deep learning-based LSTM and Transformer models. The research employs open datasets from ACN, including charging data from Caltech and JPL. Both datasets are used to train and test the models. Predictions are made for 30 days, 120 days, and 240 days ahead, with results compared to actual demand. Performance is evaluated using Mean Absolute Error (MAE) and Mean Squared Error (MSE). Compared to baseline models, the proposed LSTM-Transformer model for Caltech data shows a significant improvement at the 30-day horizon, lowering MAE by up to 17.27% and MSE by 19.79%. The accuracy improvement are minor but consistent in longer horizons (120 and 240 days), with an MAE and MSE improvement of up to 5.71% and 4.85%, respectively. The LSTM-Transformer model also shows better accuracy across all horizons for JPL data by reducing MAE and MSE by up to 24.91% and 23.17% at 30 days, 5.00% and 5.17% at 120 days, and 3.90% and 4.86% at 240 days. The results indicate that the Hybrid Transformer model outperforms the baseline models for both datasets in medium-term and long-term predictions. The 30, 120, and 240-day predictions demonstrate lower error rates with the proposed model when utilizing Caltech and JPL charging data for these time frames.

Scientific ReportsVol. 15(1)
Chang'an University (CN), Rangamati Science and Technology University (BD), Meta (United States) (US)
Chang'an University
Openalex Percentile: Top 22%
Energy Load and Power Forecasting
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.