A life cycle assessment of disposing intra-operative collected fluids, a comparative study between the Neptune 3 versus canister drainage

The Neptune 3 drainage system is developed as an alternative to canister systems for collecting surgical fluids in the operating room. This study investigates the difference in the environmental impact between Neptune 3 and canister systems, evaluating all individual stages of the product life cycle of the Neptune and canisters. Using the RECIPE model, 17 impact categories (midpoints) were defined and results were aggregated into three endpoint categories (human health, ecosystems, resources). The volume of waste was varied in a setup in a hospital in the Netherlands and included different fluid volume collection scenarios performed over seven years: high-volume (2.0-24 L waste) and low-volume (0.1-0.5 L waste). In both high and low volume procedures, Neptune 3 has a lower environmental impact compared to canisters for global warming (15-89% reduction), ozone formation terrestrial ecosystems & human health (24-91% reduction), fossil resource scarcity (36-92% reduction) and water consumption (44-106% reduction). In high volume scenarios (5 + Liters) Neptune also has a lower impact in stratospheric ozone depletion, fine particulate matter formation, terrestrial acidification for the high volume scenarios (5 L or more). In the case of ionizing radiation, freshwater eutrophication, and human carcinogenic toxicity the Neptune has a lower impact only in the very large volume procedures (10 + Liter). By aggregating the mid-point results to end-point results, it is observed that the Neptune system is beneficial for resources in each scenario, and for human health and ecosystems for procedures with larger volumes. Results from this LCA demonstrate that the Neptune 3 system is environmentally beneficial compared to canisters. This study provides valuable information for policymakers and hospital decisionmakers to treat their surgical waste in an environmentally friendly way.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-21
DOI
https://doi.org/10.1038/s41598-025-20375-1
Primary Topic
Healthcare and Environmental Waste Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A life cycle assessment of disposing intra-operative collected fluids, a comparative study between the Neptune 3 versus canister drainage

Bart van Straten, Lieke Droog, Tim Horeman, Julianne Huegel et al.
Scientific Reports
Healthcare and Environmental Waste Management
article

A life cycle assessment of disposing intra-operative collected fluids, a comparative study between the Neptune 3 versus canister drainage

Bart van Straten, Lieke Droog, Tim Horeman, Julianne Huegel, L. Tariq, J. van der Sijp, T. Hoppe
article en

Abstract

The Neptune 3 drainage system is developed as an alternative to canister systems for collecting surgical fluids in the operating room. This study investigates the difference in the environmental impact between Neptune 3 and canister systems, evaluating all individual stages of the product life cycle of the Neptune and canisters. Using the RECIPE model, 17 impact categories (midpoints) were defined and results were aggregated into three endpoint categories (human health, ecosystems, resources). The volume of waste was varied in a setup in a hospital in the Netherlands and included different fluid volume collection scenarios performed over seven years: high-volume (2.0-24 L waste) and low-volume (0.1-0.5 L waste). In both high and low volume procedures, Neptune 3 has a lower environmental impact compared to canisters for global warming (15-89% reduction), ozone formation terrestrial ecosystems & human health (24-91% reduction), fossil resource scarcity (36-92% reduction) and water consumption (44-106% reduction). In high volume scenarios (5 + Liters) Neptune also has a lower impact in stratospheric ozone depletion, fine particulate matter formation, terrestrial acidification for the high volume scenarios (5 L or more). In the case of ionizing radiation, freshwater eutrophication, and human carcinogenic toxicity the Neptune has a lower impact only in the very large volume procedures (10 + Liter). By aggregating the mid-point results to end-point results, it is observed that the Neptune system is beneficial for resources in each scenario, and for human health and ecosystems for procedures with larger volumes. Results from this LCA demonstrate that the Neptune 3 system is environmentally beneficial compared to canisters. This study provides valuable information for policymakers and hospital decisionmakers to treat their surgical waste in an environmentally friendly way.

Scientific ReportsVol. 15(1)
Leiden University (NL), Utrecht University (NL), University of Applied Sciences Leiden (NL), Medisch Centrum Haaglanden (NL), OLVG (NL), Stryker (Netherlands) (NL), VSL National Metrology Institute (NL), Stryker (United States) (US), Delft University of Technology (NL)
Stryker
Openalex Percentile: Top 60%
Healthcare and Environmental Waste Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.