In-beam range determination using an OpenPET system for helium, carbon, oxygen, and neon ion beams

<i>Objective.</i>At the National Institutes for Quantum Science and Technology, helium, carbon, oxygen, and neon ion beams are utilized together in multi-ion therapy to enhance the therapeutic efficacy of charged-particle therapy. When accelerated ions traverse a medium, a fraction will undergo nuclear interactions, some of which, in turn, produce positron-emitting nuclei. This study investigates the accuracy of ion beam range determination using the annihilation photons emitted from the nuclei measured with an in-house online PET system (OpenPET).<i>Approach.</i>A polymethyl methacrylate phantom was irradiated separately with un-scanned helium, carbon, oxygen, and neon ion beams to 1.5 Gy physical doses at the Bragg peak. Annihilation photons were measured with OpenPET. Each irradiation was simulated using the Particle and Heavy Ion Transport code System (PHITS) to obtain the predicted annihilation photon distributions. The range of beams in the phantom was determined by comparing measured and simulated planar-integrated annihilation photon distributions (PIADs). Fisher information was used to quantify the expected accuracy of range determinations.<i>Main results.</i>The measured PIADs showed good agreement with the simulated PIADs for carbon, oxygen, and neon ions. However, discrepancies were observed for helium ions, likely due to uncertainties in the cross section data used in PHITS. The range was determined within an accuracy of 2 mm for four ion species for the measurement times longer than 3 min. Neon ions had the most Fisher information for measurement times shorter than 135 s, whereas beyond that, oxygen ions had the most information, offering the highest range determination accuracy.<i>Significance.</i>The range was determined within an accuracy of 2 mm for helium, carbon, oxygen, and neon ion beams by the OpenPET measurements of 180 s. Among the four ion species, neon ions showed the highest accuracy in range determination within 135 s, while oxygen ions performed best for measurement times beyond 135 s.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-10-20
DOI
https://doi.org/10.1088/1361-6560/ae1544
Citations
2
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-beam range determination using an OpenPET system for helium, carbon, oxygen, and neon ion beams

Sodai Tanaka, Akram Mohammadi, Chie Toramatsu, Takamitsu Masuda et al.
2 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
3.04
article

In-beam range determination using an OpenPET system for helium, carbon, oxygen, and neon ion beams

Sodai Tanaka, Akram Mohammadi, Chie Toramatsu, Takamitsu Masuda, Koki Kasamatsu, Taku Inaniwa, Hideaki Tashima, Taiga Yamaya, Stewart Mein, Jiayao Sun
article en
2 citations

Abstract

<i>Objective.</i>At the National Institutes for Quantum Science and Technology, helium, carbon, oxygen, and neon ion beams are utilized together in multi-ion therapy to enhance the therapeutic efficacy of charged-particle therapy. When accelerated ions traverse a medium, a fraction will undergo nuclear interactions, some of which, in turn, produce positron-emitting nuclei. This study investigates the accuracy of ion beam range determination using the annihilation photons emitted from the nuclei measured with an in-house online PET system (OpenPET).<i>Approach.</i>A polymethyl methacrylate phantom was irradiated separately with un-scanned helium, carbon, oxygen, and neon ion beams to 1.5 Gy physical doses at the Bragg peak. Annihilation photons were measured with OpenPET. Each irradiation was simulated using the Particle and Heavy Ion Transport code System (PHITS) to obtain the predicted annihilation photon distributions. The range of beams in the phantom was determined by comparing measured and simulated planar-integrated annihilation photon distributions (PIADs). Fisher information was used to quantify the expected accuracy of range determinations.<i>Main results.</i>The measured PIADs showed good agreement with the simulated PIADs for carbon, oxygen, and neon ions. However, discrepancies were observed for helium ions, likely due to uncertainties in the cross section data used in PHITS. The range was determined within an accuracy of 2 mm for four ion species for the measurement times longer than 3 min. Neon ions had the most Fisher information for measurement times shorter than 135 s, whereas beyond that, oxygen ions had the most information, offering the highest range determination accuracy.<i>Significance.</i>The range was determined within an accuracy of 2 mm for helium, carbon, oxygen, and neon ion beams by the OpenPET measurements of 180 s. Among the four ion species, neon ions showed the highest accuracy in range determination within 135 s, while oxygen ions performed best for measurement times beyond 135 s.

Physics in Medicine and BiologyVol. 70(22)
Shanghai Medical Information Center (CN), Fudan University Shanghai Cancer Center (CN), Heidelberger Institut für Radioonkologie (DE), National Institutes for Quantum Science and Technology (JP)
Openalex Percentile: Top 8%
Radiation Therapy and Dosimetry
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.