Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products

The analysis of 1,3-dichloropropan-2-ol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in paper products and cardboard boxes used as food contact materials is of great importance due to the potential health risks associated with the intake of these contaminants. Both compounds, which originate from wet strength agents used in paper production, pose significant health concerns: 1,3-DCP and 3-MCPD are classified as possibly carcinogenic to humans and suspected to be carcinogenic in humans, respectively. This study presents a novel, automated analytical method for the analysis of a cold water extract-a widely used procedure for isolating these analytes from paper products and cardboard boxes. Method development included the implementation of vortex-assisted liquid-liquid microextraction (VALLME) with a focus on reducing solvent consumption and improving environmental sustainability and the systematic investigation of derivatization techniques. Optimization of the extraction solvent, extraction time, and derivatization parameters using vial-based and injector-based approaches resulted in a lean and rapid method with low limits of detection (0.01 µg/L for 1,3-DCP and 0.16 µg/L for 3-MCPD). The method showed good precision with intra-day repeatabilities of 3.6-3.7% for 1,3-DCP and 3.6-5.9% for 3-MCPD and inter-day repeatabilities of 2.6-3.6% and 4.0-7.6%, respectively. Recoveries ranged from 100 to 102% for 1,3-DCP and from 90 to 99% for 3-MCPD. Comparative assessment with a reference method confirmed good precision and comparability of the method. Improved environmental performance was quantified by the analytical greenness metric for sample preparation.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2025-10-21
DOI
https://doi.org/10.1007/s00216-025-06133-2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products

Torsten C. Schmidt, Malte Hübschen, Fabrian Brenz
Analytical and Bioanalytical Chemistry
Analytical chemistry methods development
article

Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products

Torsten C. Schmidt, Malte Hübschen, Fabrian Brenz
article en

Abstract

The analysis of 1,3-dichloropropan-2-ol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in paper products and cardboard boxes used as food contact materials is of great importance due to the potential health risks associated with the intake of these contaminants. Both compounds, which originate from wet strength agents used in paper production, pose significant health concerns: 1,3-DCP and 3-MCPD are classified as possibly carcinogenic to humans and suspected to be carcinogenic in humans, respectively. This study presents a novel, automated analytical method for the analysis of a cold water extract-a widely used procedure for isolating these analytes from paper products and cardboard boxes. Method development included the implementation of vortex-assisted liquid-liquid microextraction (VALLME) with a focus on reducing solvent consumption and improving environmental sustainability and the systematic investigation of derivatization techniques. Optimization of the extraction solvent, extraction time, and derivatization parameters using vial-based and injector-based approaches resulted in a lean and rapid method with low limits of detection (0.01 µg/L for 1,3-DCP and 0.16 µg/L for 3-MCPD). The method showed good precision with intra-day repeatabilities of 3.6-3.7% for 1,3-DCP and 3.6-5.9% for 3-MCPD and inter-day repeatabilities of 2.6-3.6% and 4.0-7.6%, respectively. Recoveries ranged from 100 to 102% for 1,3-DCP and from 90 to 99% for 3-MCPD. Comparative assessment with a reference method confirmed good precision and comparability of the method. Improved environmental performance was quantified by the analytical greenness metric for sample preparation.

Analytical and Bioanalytical ChemistryVol. 417(28)
Chemisches und Veterinäruntersuchungsamt Münsterland-Emscher-Lippe (DE), Schmolz Bickenbach (Germany) (DE), University of Duisburg-Essen (DE)
Universität Duisburg-Essen
Openalex Percentile: Top 66%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.