Stability of a Bi-disperse Microbubble Population for Advanced Ultrasound Localization Microscopy

Ultrasound Localization Microscopy (ULM) overcomes the conventional diffraction limit by precisely localizing intravenously injected microbubbles (MBs), enabling microscopic resolution imaging of the vascular network. The long acquisition time necessary to accumulate a sufficient amount of MB signals within the (micro-)vascular region of interest hinders ULM clinical applicability. To address this limitation, we propose a novel approach based on a bi-disperse MB population, composed of two distinct monodisperse MB populations. By uncoupling this population, higher overall MB concentrations can be used, thereby reducing acquisition times. Uncoupling is achieved through a signal processing pipeline that exploits the strong nonlinear response of MBs when their resonance frequency matches the transmission frequency. In this study, we evaluate the in vitro stability of the bi-disperse MB population and assess its separability. Our results confirm both the temporal stability and the effective acoustic separation of the bi-disperse MB population, supporting its potential to enhance ULM performance and accelerate its clinical translation.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1109/ius62464.2025.11201571
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability of a Bi-disperse Microbubble Population for Advanced Ultrasound Localization Microscopy

Giulia Tuccio, Libertario Demi, Lisa Te Winkel, Wim van Hoeve et al.
Ultrasound and Hyperthermia Applications
article

Stability of a Bi-disperse Microbubble Population for Advanced Ultrasound Localization Microscopy

Giulia Tuccio, Libertario Demi, Lisa Te Winkel, Wim van Hoeve, Corinne Bruggeman
article en

Abstract

Ultrasound Localization Microscopy (ULM) overcomes the conventional diffraction limit by precisely localizing intravenously injected microbubbles (MBs), enabling microscopic resolution imaging of the vascular network. The long acquisition time necessary to accumulate a sufficient amount of MB signals within the (micro-)vascular region of interest hinders ULM clinical applicability. To address this limitation, we propose a novel approach based on a bi-disperse MB population, composed of two distinct monodisperse MB populations. By uncoupling this population, higher overall MB concentrations can be used, thereby reducing acquisition times. Uncoupling is achieved through a signal processing pipeline that exploits the strong nonlinear response of MBs when their resonance frequency matches the transmission frequency. In this study, we evaluate the in vitro stability of the bi-disperse MB population and assess its separability. Our results confirm both the temporal stability and the effective acoustic separation of the bi-disperse MB population, supporting its potential to enhance ULM performance and accelerate its clinical translation.

University of Trento (IT), Teva Pharmaceuticals (Netherlands) (NL)
Openalex Percentile: Top 71%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.