Real-Time Histogram-Based Automated Signal Exposure Correction on FPGA for Optoacoustic Imaging

Optoacoustic (OA) imaging combines optical excitation and ultrasound receive beamforming to render images of deep tissues with strong functional contrast, coupled with high spatial and temporal resolution. The widespread adoption of OA imaging critically depends on user-friendly, compact systems not requiring experts for manual parameter tuning. Manual adjustments for optimal Signal-to-Noise Ratio (SNR), often tailored to each target, impede high-frame-rate acquisition and are prone to image degradation if done incorrectly. To address these challenges, we propose a fully automated histogram-based signal exposure correction method based on Automated Gain Control (AGC). Our approach analyzes the histogram distribution of raw Analog Front-end (AFE) data to classify exposure conditions and dynamically adjust gain settings without user intervention. The algorithm is implemented on a mid-range FPGA (Xilinx Kria K26), operating at 400 MHz, across 16 input channels, and with minimal hardware overhead. We validate our approach on an in-vivo human angiography dataset and demonstrate that it reliably avoids overexposed and underexposed configurations and achieves image quality metrics comparable to expert-tuned acquisitions.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1109/ius62464.2025.11201423
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Histogram-Based Automated Signal Exposure Correction on FPGA for Optoacoustic Imaging

Federico Villani, Luca Benini, Andrea Cossettini, Daniel Razansky et al.
Photoacoustic and Ultrasonic Imaging
article

Real-Time Histogram-Based Automated Signal Exposure Correction on FPGA for Optoacoustic Imaging

Federico Villani, Luca Benini, Andrea Cossettini, Daniel Razansky, Xiang Liu, Giusy Spacone, Viturin Schuhmacher
article en

Abstract

Optoacoustic (OA) imaging combines optical excitation and ultrasound receive beamforming to render images of deep tissues with strong functional contrast, coupled with high spatial and temporal resolution. The widespread adoption of OA imaging critically depends on user-friendly, compact systems not requiring experts for manual parameter tuning. Manual adjustments for optimal Signal-to-Noise Ratio (SNR), often tailored to each target, impede high-frame-rate acquisition and are prone to image degradation if done incorrectly. To address these challenges, we propose a fully automated histogram-based signal exposure correction method based on Automated Gain Control (AGC). Our approach analyzes the histogram distribution of raw Analog Front-end (AFE) data to classify exposure conditions and dynamically adjust gain settings without user intervention. The algorithm is implemented on a mid-range FPGA (Xilinx Kria K26), operating at 400 MHz, across 16 input channels, and with minimal hardware overhead. We validate our approach on an in-vivo human angiography dataset and demonstrate that it reliably avoids overexposed and underexposed configurations and achieves image quality metrics comparable to expert-tuned acquisitions.

ETH Zurich (CH)
Openalex Percentile: Top 71%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.