Novel Ultrasound Dual Array Method for Precise Blood Flow Measurement

Blood flow volume (BFV) is a fundamental indicator of cardiovascular (CV) health, reflecting the dynamic state of the circulatory system and the heart's ability to perfuse tissues effectively. In critical care settings, such as intensive care units, continuous and accurate monitoring of BFV is essential for early detection of hemodynamic instability and prevention of adverse cardiovascular events, including hypotension, organ hypoperfusion, and cardiac arrest.This work introduces a novel dual-array ultrasound approach to measure BFV by using two cross-sectional views to extract the Doppler angle, flow velocities, and vessel area. The proposed solution allows for an operator-free and accurate estimation of the Doppler angle and therefore it is truly suitable to be integrated into wearable applications.The system was tested by exploiting the ULA-OP 256 open platform, connected to two 7.5-MHz linear arrays. Experimental validation was conducted on an 8-mm diameter vessel within a flow phantom, with flow controlled by a programmable peristaltic pump and monitored via a flow sensor. The estimated BFV showed good agreement with reference values, showing an average underestimation of 3.8%. Furthermore, the best-fit linear regression yielded an angular coefficient of 1.09 and a coefficient of determination R<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> of 0.98, confirming the method’s good performance.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1109/ius62464.2025.11201810
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Ultrasound Dual Array Method for Precise Blood Flow Measurement

Leonardo Baldasarre, Marco Travagliati, Alessandro Ramalli, Federica Confalonieri et al.
Flow Measurement and Analysis
article

Novel Ultrasound Dual Array Method for Precise Blood Flow Measurement

Leonardo Baldasarre, Marco Travagliati, Alessandro Ramalli, Federica Confalonieri, Paolo Mattesini
article en

Abstract

Blood flow volume (BFV) is a fundamental indicator of cardiovascular (CV) health, reflecting the dynamic state of the circulatory system and the heart's ability to perfuse tissues effectively. In critical care settings, such as intensive care units, continuous and accurate monitoring of BFV is essential for early detection of hemodynamic instability and prevention of adverse cardiovascular events, including hypotension, organ hypoperfusion, and cardiac arrest.This work introduces a novel dual-array ultrasound approach to measure BFV by using two cross-sectional views to extract the Doppler angle, flow velocities, and vessel area. The proposed solution allows for an operator-free and accurate estimation of the Doppler angle and therefore it is truly suitable to be integrated into wearable applications.The system was tested by exploiting the ULA-OP 256 open platform, connected to two 7.5-MHz linear arrays. Experimental validation was conducted on an 8-mm diameter vessel within a flow phantom, with flow controlled by a programmable peristaltic pump and monitored via a flow sensor. The estimated BFV showed good agreement with reference values, showing an average underestimation of 3.8%. Furthermore, the best-fit linear regression yielded an angular coefficient of 1.09 and a coefficient of determination R<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> of 0.98, confirming the method’s good performance.

Ambiente Italia (Italy) (IT), University of Florence (IT)
Openalex Percentile: Top 65%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.