Experimental Validation of continuous Emission Ultrafast Ultrasound Imaging

Conventional ultrasound imaging relies on the pulse–echo (PE) paradigm, which inherently limits the frame rate and leaves the system blind during the receive period. To address these limitations, Continuous Emission Ultrasound Imaging (CEUI) has been proposed as a new approach that continuously insonifies the medium using a coded excitation. Owing to its continuous interaction with the medium, CEUI can in theory achieve a frame rate limited only by the sampling frequency. This work presents the first experimental validation of CEUI in a 1D setup using separate transmit and receive transducers for Motion-Mode imaging. Compared to PE performed at different PRFs (up to 10 kHz), CEUI achieved a frame rate of 1 MHz, enabling precise tracking of both slow and fast motions. These results demonstrate the feasibility of CEUI and its potential to surpass PE imaging in high frame rate applications.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1109/ius62464.2025.11201812
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of continuous Emission Ultrafast Ultrasound Imaging

Hervé Liebgott, Barbara Nicolas, Adrian Basarab, Axel Adam et al.
Flow Measurement and Analysis
article

Experimental Validation of continuous Emission Ultrafast Ultrasound Imaging

Hervé Liebgott, Barbara Nicolas, Adrian Basarab, Axel Adam, Mohamed Tamraoui
article en

Abstract

Conventional ultrasound imaging relies on the pulse–echo (PE) paradigm, which inherently limits the frame rate and leaves the system blind during the receive period. To address these limitations, Continuous Emission Ultrasound Imaging (CEUI) has been proposed as a new approach that continuously insonifies the medium using a coded excitation. Owing to its continuous interaction with the medium, CEUI can in theory achieve a frame rate limited only by the sampling frequency. This work presents the first experimental validation of CEUI in a 1D setup using separate transmit and receive transducers for Motion-Mode imaging. Compared to PE performed at different PRFs (up to 10 kHz), CEUI achieved a frame rate of 1 MHz, enabling precise tracking of both slow and fast motions. These results demonstrate the feasibility of CEUI and its potential to surpass PE imaging in high frame rate applications.

Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), Lyon College (US), Institut National des Sciences Appliquées de Lyon (FR)
Openalex Percentile: Top 66%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.