Environmental and Serological Monitoring of Porcine Circovirus by Loop-Mediated Isothermal Amplification in Pig Farms

Despite the widespread use of Porcine circovirus type 2 (PCV2) vaccination, subclinical infection persists and remains a concern due to its economic impact. Therefore, continuous herd-level monitoring is essential to assess the dynamics of this infection on farms and minimize its impact. This study evaluated the applicability of a loop-mediated isothermal amplification (LAMP) assay for PCV2 detection in serum, air, and surface samples collected under field conditions. In addition, a simplified Direct LAMP protocol, omitting DNA extraction, was compared with quantitative PCR (qPCR) as the reference method. A total of 360 samples from PCV2 vaccinated and unvaccinated fattening farms were analyzed. Diagnostic performance was assessed in terms of sensitivity, specificity, predictive values, and concordance with qPCR, using Cohen's kappa coefficient (κ). LAMP showed higher agreement with qPCR (κ = 0.52) than Direct LAMP (κ = 0.16). Serum samples provided the most reliable results when DNA extraction was performed, reaching substantial agreement with qPCR (κ = 0.76). However, Direct LAMP applied directly to serum was negatively affected by inhibitory substances, resulting in a significant drop in sensitivity. In contrast both air and surface samples yielded comparable results between LAMP and Direct LAMP, without the need for DNA extraction. Notably, LAMP-based assays detected PCV2 circulation earlier than qPCR, particularly in environmental samples. These findings demonstrate the potential of LAMP as a practical alternative to qPCR for PCV2 monitoring. While DNA extraction remains essential for reliable detection in serum, Direct LAMP represents a promising strategy for environmental surveillance, enabling rapid, low-cost, and on-farm diagnostics.

Authors

Institutions

Publication Details

Journal
Veterinary Sciences
Published
2025-10-18
DOI
https://doi.org/10.3390/vetsci12101011
Primary Topic
Animal Virus Infections Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental and Serological Monitoring of Porcine Circovirus by Loop-Mediated Isothermal Amplification in Pig Farms

Alexandre Lamas, Gonzalo López‐Lorenzo, Alejandro Garrido‐Maestu
Veterinary Sciences
Animal Virus Infections Studies
article

Environmental and Serological Monitoring of Porcine Circovirus by Loop-Mediated Isothermal Amplification in Pig Farms

Alexandre Lamas, Gonzalo López‐Lorenzo, Alejandro Garrido‐Maestu
article en

Abstract

Despite the widespread use of Porcine circovirus type 2 (PCV2) vaccination, subclinical infection persists and remains a concern due to its economic impact. Therefore, continuous herd-level monitoring is essential to assess the dynamics of this infection on farms and minimize its impact. This study evaluated the applicability of a loop-mediated isothermal amplification (LAMP) assay for PCV2 detection in serum, air, and surface samples collected under field conditions. In addition, a simplified Direct LAMP protocol, omitting DNA extraction, was compared with quantitative PCR (qPCR) as the reference method. A total of 360 samples from PCV2 vaccinated and unvaccinated fattening farms were analyzed. Diagnostic performance was assessed in terms of sensitivity, specificity, predictive values, and concordance with qPCR, using Cohen's kappa coefficient (κ). LAMP showed higher agreement with qPCR (κ = 0.52) than Direct LAMP (κ = 0.16). Serum samples provided the most reliable results when DNA extraction was performed, reaching substantial agreement with qPCR (κ = 0.76). However, Direct LAMP applied directly to serum was negatively affected by inhibitory substances, resulting in a significant drop in sensitivity. In contrast both air and surface samples yielded comparable results between LAMP and Direct LAMP, without the need for DNA extraction. Notably, LAMP-based assays detected PCV2 circulation earlier than qPCR, particularly in environmental samples. These findings demonstrate the potential of LAMP as a practical alternative to qPCR for PCV2 monitoring. While DNA extraction remains essential for reliable detection in serum, Direct LAMP represents a promising strategy for environmental surveillance, enabling rapid, low-cost, and on-farm diagnostics.

Veterinary SciencesVol. 12(10)
Universidade de Santiago de Compostela (ES), Instituto de Investigacións Mariñas (ES), Institut de Ciències del Mar (ES)
Openalex Percentile: Top 65%
Animal Virus Infections Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.