Particle Image Velocimetry Algorithm Based on Spike Camera Adaptive Integration

In particle image velocimetry (PIV), overexposure is particularly common in regions with high illumination. In particular, strong scattering or background reflection at the liquid-gas interface will make the overexposure phenomenon more obvious, resulting in local pixel saturation, which will significantly reduce the particle image quality, and thus reduce the particle recognition rate and the accuracy of velocity field estimation. This study addresses the overexposure challenges in particle image velocimetry applications, mainly to address the challenge that the velocity field cannot be measured due to the difficulty in effectively detecting particles in the exposed area. In order to address the challenge of overexposure, this paper does not use traditional frame-based high-speed cameras, but instead proposes a particle image velocimetry algorithm based on adaptive integral spike camera data using a neuromorphic vision sensor (NVS). Specifically, by performing target-background segmentation on high-frequency digital spike signals, the method suppresses high illumination background regions and thus effectively mitigates overexposure. Then the spike data are further adaptively integrated based on both regional background illumination characteristics and the spike frequency features of particles with varying velocities, resulting in high signal-to-noise ratio (SNR) reconstructed particle images. Flow field computation is subsequently conducted using the reconstructed particle images, with validation through both simulation and experiment. In simulation, in the overexposed area, the average flow velocity estimation error of frame-based cameras is 8.594 times that of spike-based cameras. In the experiments, the spike camera successfully captured continuous high-density particle trajectories, yielding measurable and continuous velocity fields. Experimental results demonstrate that the proposed particle image velocimetry algorithm based on the adaptive integration of the spike camera effectively addresses overexposure challenges caused by high illumination of the liquid-gas interface in flow field measurements.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-10-19
DOI
https://doi.org/10.3390/s25206468
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Particle Image Velocimetry Algorithm Based on Spike Camera Adaptive Integration

Pengyu Lv, Xiaoqiang Li, Yuhao Huang, Tiejun Huang et al.
Sensors
CCD and CMOS Imaging Sensors
article

Particle Image Velocimetry Algorithm Based on Spike Camera Adaptive Integration

Pengyu Lv, Xiaoqiang Li, Yuhao Huang, Tiejun Huang, Cynthia Wu, Yichao Wang, Yuan Li, Hongyuan Li
article en

Abstract

In particle image velocimetry (PIV), overexposure is particularly common in regions with high illumination. In particular, strong scattering or background reflection at the liquid-gas interface will make the overexposure phenomenon more obvious, resulting in local pixel saturation, which will significantly reduce the particle image quality, and thus reduce the particle recognition rate and the accuracy of velocity field estimation. This study addresses the overexposure challenges in particle image velocimetry applications, mainly to address the challenge that the velocity field cannot be measured due to the difficulty in effectively detecting particles in the exposed area. In order to address the challenge of overexposure, this paper does not use traditional frame-based high-speed cameras, but instead proposes a particle image velocimetry algorithm based on adaptive integral spike camera data using a neuromorphic vision sensor (NVS). Specifically, by performing target-background segmentation on high-frequency digital spike signals, the method suppresses high illumination background regions and thus effectively mitigates overexposure. Then the spike data are further adaptively integrated based on both regional background illumination characteristics and the spike frequency features of particles with varying velocities, resulting in high signal-to-noise ratio (SNR) reconstructed particle images. Flow field computation is subsequently conducted using the reconstructed particle images, with validation through both simulation and experiment. In simulation, in the overexposed area, the average flow velocity estimation error of frame-based cameras is 8.594 times that of spike-based cameras. In the experiments, the spike camera successfully captured continuous high-density particle trajectories, yielding measurable and continuous velocity fields. Experimental results demonstrate that the proposed particle image velocimetry algorithm based on the adaptive integration of the spike camera effectively addresses overexposure challenges caused by high illumination of the liquid-gas interface in flow field measurements.

SensorsVol. 25(20)
Beijing University of Posts and Telecommunications (CN), Peking University (CN), Vi Technology (United States) (US), Robotics Research (United States) (US)
National Natural Science Foundation of China, Beijing Nova Program
Openalex Percentile: Top 70%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.