Experimental demonstration of the sine condition test plus, part 1: development of an alignment method using deflectometry and the sine condition test

The sine condition test plus (SCT+) is a novel alignment technique, to our knowledge, that integrates two metrology concepts, deflectometry and the sine condition test. This paper presents an experimental validation of the SCT+, demonstrating its ability to measure the five aberrations that indicate misalignment and comparing these measurements with predictions. The experimental results of the SCT+ show a strong correlation with predicted values within expected uncertainties, confirming the accuracy and reliability of the method. Additionally, the efficacy of the SCT+ is evaluated with a cross-check using interferometry. These findings strongly support that the SCT+ can provide accurate and efficient optical alignment, which will be presented in a subsequent paper.

Authors

Publication Details

Journal
Applied Optics
Published
2025-10-20
DOI
https://doi.org/10.1364/ao.570848
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental demonstration of the sine condition test plus, part 1: development of an alignment method using deflectometry and the sine condition test

Hyemin Yoo, Matthew Dubin
Applied Optics
Structural Health Monitoring Techniques
article

Experimental demonstration of the sine condition test plus, part 1: development of an alignment method using deflectometry and the sine condition test

Hyemin Yoo, Matthew Dubin
article en

Abstract

The sine condition test plus (SCT+) is a novel alignment technique, to our knowledge, that integrates two metrology concepts, deflectometry and the sine condition test. This paper presents an experimental validation of the SCT+, demonstrating its ability to measure the five aberrations that indicate misalignment and comparing these measurements with predictions. The experimental results of the SCT+ show a strong correlation with predicted values within expected uncertainties, confirming the accuracy and reliability of the method. Additionally, the efficacy of the SCT+ is evaluated with a cross-check using interferometry. These findings strongly support that the SCT+ can provide accurate and efficient optical alignment, which will be presented in a subsequent paper.

Applied OpticsVol. 64(32)
Openalex Percentile: Top 69%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.