An Analysis of the Chemical and Physical Properties of a Silver Carboxylate Titanium-Dioxide Polydimethylsiloxane Antimicrobial Matrix on Orthopedic Implant Materials

Consistent with previous work, the 10× AgCar coating demonstrated the best results for inhibitory behavior on two distinct fronts: mechanically, through roughness and increased hydrophobicity, and chemically, through AgCar elution activity. Furthermore, the 10× coating will likely not impair the durability or elasticity of the implant within the body or silicone prosthetic liners. Thus, the 95% TiO<sub>2</sub>:5% PDMS matrix doped with a 10× AgCar concentration is a prime candidate for clinical application consideration.

Authors

Institutions

Publication Details

Journal
Surgical Infections
Published
2025-10-20
DOI
https://doi.org/10.1177/10962964251389154
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Analysis of the Chemical and Physical Properties of a Silver Carboxylate Titanium-Dioxide Polydimethylsiloxane Antimicrobial Matrix on Orthopedic Implant Materials

Dominique M. Dockery, Christopher T. Born, Odelia Cooper, Valentin Antoci et al.
Surgical Infections
Bone Tissue Engineering Materials
article

An Analysis of the Chemical and Physical Properties of a Silver Carboxylate Titanium-Dioxide Polydimethylsiloxane Antimicrobial Matrix on Orthopedic Implant Materials

Dominique M. Dockery, Christopher T. Born, Odelia Cooper, Valentin Antoci, José‐Tomás Navarro, Sai Allu, Dioscaris Garcia, Neel Vishwanath, Nayoung Kim, R.J.I. Bain
article en

Abstract

Consistent with previous work, the 10× AgCar coating demonstrated the best results for inhibitory behavior on two distinct fronts: mechanically, through roughness and increased hydrophobicity, and chemically, through AgCar elution activity. Furthermore, the 10× coating will likely not impair the durability or elasticity of the implant within the body or silicone prosthetic liners. Thus, the 95% TiO<sub>2</sub>:5% PDMS matrix doped with a 10× AgCar concentration is a prime candidate for clinical application consideration.

Surgical InfectionsVol. 27(2)
Brown University (US), Rhode Island Hospital (US)
Openalex Percentile: Top 71%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.