Portable and Visualized X-ray Dose Rate Detection and Imaging Utilizing Br-Doped CsCdCl <sub>3</sub> Crystals

X-ray detectors are widely used for nondestructive detection in our daily lives, industries, and scientific studies. While their development has seen significant progress, the detection of radiation dose rates still requires expensive equipment and complex calibration procedures. Herein, we introduce a portable and visualized self-calibrated real-time X-ray dose rate detector based on Br-doped CsCdCl<sub>3</sub> crystals. This material exhibits a dual-emission band originating from two different self-trapped exciton recombination pathways. Importantly, Br-doped CsCdCl<sub>3</sub> crystals also exhibit a dual radioluminescence response under X-ray excitation. When the X-ray dose rate increases, the radioluminescence intensity at 480 nm increases at the expense of the peak at 595 nm. Based on the radioluminescence intensity ratio at these two wavelengths, a self-calibrated X-ray dose rate detector is constructed, which delivers a high relative sensitivity of 6% (mGy<sub>air</sub> s<sup>-1</sup>)<sup>-1</sup> at 0.6 mGy<sub>air</sub> s<sup>-1</sup>. Moreover, we have successfully achieved real-time visualization of X-ray dose rates by extracting color coordinates from photographs of luminescent Br-doped CsCdCl<sub>3</sub> crystals captured by a smartphone. Finally, we also demonstrated the application of Br-doped CsCdCl<sub>3</sub> powders embedded into a flexible polymer film for simultaneous X-ray imaging and dose rate detection.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-10-20
DOI
https://doi.org/10.1021/acsami.5c16460
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable and Visualized X-ray Dose Rate Detection and Imaging Utilizing Br-Doped CsCdCl 3 Crystals

Hui Peng, Bingsuo Zou, Andrey L. Rogach, Xue Zhao et al.
1 citations
ACS Applied Materials & Interfaces
Radiation Detection and Scintillator Technologies
1.88
article

Portable and Visualized X-ray Dose Rate Detection and Imaging Utilizing Br-Doped CsCdCl 3 Crystals

Hui Peng, Bingsuo Zou, Andrey L. Rogach, Xue Zhao, Qilin Wei, Xiaokang Li, Linghang Kong, Bingkun Chen
article en
1 citations

Abstract

X-ray detectors are widely used for nondestructive detection in our daily lives, industries, and scientific studies. While their development has seen significant progress, the detection of radiation dose rates still requires expensive equipment and complex calibration procedures. Herein, we introduce a portable and visualized self-calibrated real-time X-ray dose rate detector based on Br-doped CsCdCl<sub>3</sub> crystals. This material exhibits a dual-emission band originating from two different self-trapped exciton recombination pathways. Importantly, Br-doped CsCdCl<sub>3</sub> crystals also exhibit a dual radioluminescence response under X-ray excitation. When the X-ray dose rate increases, the radioluminescence intensity at 480 nm increases at the expense of the peak at 595 nm. Based on the radioluminescence intensity ratio at these two wavelengths, a self-calibrated X-ray dose rate detector is constructed, which delivers a high relative sensitivity of 6% (mGy<sub>air</sub> s<sup>-1</sup>)<sup>-1</sup> at 0.6 mGy<sub>air</sub> s<sup>-1</sup>. Moreover, we have successfully achieved real-time visualization of X-ray dose rates by extracting color coordinates from photographs of luminescent Br-doped CsCdCl<sub>3</sub> crystals captured by a smartphone. Finally, we also demonstrated the application of Br-doped CsCdCl<sub>3</sub> powders embedded into a flexible polymer film for simultaneous X-ray imaging and dose rate detection.

ACS Applied Materials & InterfacesVol. 17(43)
Beijing Institute of Technology (CN), Xidian University (CN), Guangxi University (CN), Shandong University (CN), City University of Hong Kong (HK), Applied Photonics (United Kingdom) (GB), General Research Institute for Nonferrous Metals (China) (CN), Cathay Photonics (China) (CN)
Openalex Percentile: Top 12%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.