Shear Strength of Double-Skin Truss-Reinforced Composite Shear Walls: Finite Element Analysis

This study investigates the shear behavior of double-skin truss-reinforced composite shear walls through finite element analysis validated by published tests. Parametric studies reveal that the shear strength increases with the axial compression ratio up to a threshold of 0.6, beyond which it declines. However, increasing the aspect ratio significantly decreases the shear strength when the aspect ratio does not exceed 2.5. Additionally, increasing the spacing–thickness ratio reduces the shear strength, with a recommended limit of 60. Truss connector specifications are found to have a minor impact on the shear resistance. A new design formula for predicting the ultimate shear strength is established based on finite element analysis (FEA), which yields relatively conservative predictions with acceptable accuracy.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-10-20
DOI
https://doi.org/10.3390/buildings15203788
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear Strength of Double-Skin Truss-Reinforced Composite Shear Walls: Finite Element Analysis

D.D. Tang, Jianhong Han, Panpan Tian, Zhi‐Xin Shan
1 citations
Buildings
Structural Load-Bearing Analysis
0.95
article

Shear Strength of Double-Skin Truss-Reinforced Composite Shear Walls: Finite Element Analysis

D.D. Tang, Jianhong Han, Panpan Tian, Zhi‐Xin Shan
article en
1 citations

Abstract

This study investigates the shear behavior of double-skin truss-reinforced composite shear walls through finite element analysis validated by published tests. Parametric studies reveal that the shear strength increases with the axial compression ratio up to a threshold of 0.6, beyond which it declines. However, increasing the aspect ratio significantly decreases the shear strength when the aspect ratio does not exceed 2.5. Additionally, increasing the spacing–thickness ratio reduces the shear strength, with a recommended limit of 60. Truss connector specifications are found to have a minor impact on the shear resistance. A new design formula for predicting the ultimate shear strength is established based on finite element analysis (FEA), which yields relatively conservative predictions with acceptable accuracy.

BuildingsVol. 15(20)
Xinjiang Institute of Engineering (CN), Southeast University (CN), Xinjiang University (CN)
Openalex Percentile: Top 20%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shear Strength of Double-Skin Truss-Reinforced Composite Shear Walls: Finite Element Analysis — D.D. Tang, Jianhong Han, et al. · Buildings (2025) | TGRS Research Map | TGRS