Wear behavior of different SiC and WC reinforced high entropy alloys deposited by the spark emmission procedure on a AISI 1010 steel

Abstract In this study, CrMnFeCoNi (HEA) coating electrodes containing different proportions of reinforcement elements were produced by arc melting reverse vacuum system and the steel surface was coated by electro-spark deposition (ESD) method. According to the obtained data; while the microstructures for unreinforced HEA consisted of FCC structure, M 7 C 3 , M 23 C 6 and phases belonging to reinforcement elements were detected together with FCC structure in SiC and WC reinforcement. Good bonding was detected at the matrix-coating interface and layer thicknesses varied between 18 µm and 60 µm, and micro hardnesses varied between 256 HV and 578 HV. According to the wear tests, the steel wear rate decreased up to 32 times depending on the reinforcement element ratio and type.

Authors

Institutions

Publication Details

Journal
Materials Testing
Published
2025-10-20
DOI
https://doi.org/10.1515/mt-2025-0233
Primary Topic
Surface Treatment and Coatings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wear behavior of different SiC and WC reinforced high entropy alloys deposited by the spark emmission procedure on a AISI 1010 steel

Ersan Mertgenç, Yusuf Kayalı
Materials Testing
Surface Treatment and Coatings
article

Wear behavior of different SiC and WC reinforced high entropy alloys deposited by the spark emmission procedure on a AISI 1010 steel

Ersan Mertgenç, Yusuf Kayalı
article en

Abstract

Abstract In this study, CrMnFeCoNi (HEA) coating electrodes containing different proportions of reinforcement elements were produced by arc melting reverse vacuum system and the steel surface was coated by electro-spark deposition (ESD) method. According to the obtained data; while the microstructures for unreinforced HEA consisted of FCC structure, M 7 C 3 , M 23 C 6 and phases belonging to reinforcement elements were detected together with FCC structure in SiC and WC reinforcement. Good bonding was detected at the matrix-coating interface and layer thicknesses varied between 18 µm and 60 µm, and micro hardnesses varied between 256 HV and 578 HV. According to the wear tests, the steel wear rate decreased up to 32 times depending on the reinforcement element ratio and type.

Materials TestingVol. 67(11)
Afyon Kocatepe University (TR)
Openalex Percentile: Top 69%
Surface Treatment and Coatings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.