Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays

Accurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.

Authors

Institutions

Publication Details

Journal
Ultrasonics
Published
2026-05-01
DOI
https://doi.org/10.1016/j.ultras.2026.108126
Primary Topic
Radio Astronomy Observations and Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays

Adrien Bertolo, Mathieu Pernot, Thomas Deffieux, Guillaume Goudot et al.
Ultrasonics
Radio Astronomy Observations and Technology
article

Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays

Adrien Bertolo, Mathieu Pernot, Thomas Deffieux, Guillaume Goudot, Henri‐Arthur Leroy, Mickael Tanter
article en

Abstract

Accurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.

UltrasonicsVol. 166
Centre National de la Recherche Scientifique (FR), Inserm (FR), Université Paris Sciences et Lettres (FR), Assistance Publique – Hôpitaux de Paris (FR), Hôpital Européen (FR), Physique pour la médecine Paris (FR), ESPCI Paris (FR)
Institut National de la Santé et de la Recherche Médicale, Ministère de l'Enseignement Supérieur et de la Recherche, Ministère de l'Enseignement supérieur, de la Recherche et de l'Innovation
Openalex Percentile: Top 99%
Radio Astronomy Observations and Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.