Assessing internal mechanical damage in aramid ropes using ATR-FTIR spectroscopy

We present a novel approach to use Attenuated Total Reflectance Fourier-Transform Infrared (ATR-FTIR) spectroscopy for assessing internal damage in Twaron® aramid ropes subjected to cyclic bending fatigue loading at various stages of the fatigue life. After testing, rope specimens were analysed under two configurations: (1) an “open-strand” configuration, where an individual strand was untwisted and isolated from a double-twisted three-strand rope to enable direct ATR measurement of the heavily damaged filaments, and (2) a “closed-rope” configuration, where measurements were conducted at the observable strand–strand interface, sampling a broader transverse region consisting of both highly and less-damaged filaments. The main aim of studying these two configurations was to evaluate ATR-FTIR as a non-destructive technique for internal damage characterisation in industrial aramid ropes. The effect of fibre orientation on FTIR spectra was examined to isolate it from the effect of mechanical damage on the spectra. FTIR spectral analysis involved normalising absorbance spectra to an internal reference band and tracking changes in peak intensity at 1110 cm -1 as a damage indicator. In open-strand measurements, the 1110 cm -1 absorbance showed a sharp initial decline before stabilising at higher damage levels. In contrast, closed-rope measurements exhibited a more gradual reduction, reflecting the averaging effect of mixed damage states across the measured region. A bounded exponential fit of the absorbance–damage relationship showed a strong correlation with damage progression, confirming that FTIR-derived peak absorbance ratios serve as reliable indicators of internal degradation. Moreover, changes in rope size (3- vs. 6-yarn strands) showed a minimal effect on spectral trends, supporting the scalability of the method to larger industrial ropes. Additional imaging using electron microscopy and computed tomography (CT) scanning revealed progressive fibrillation and peeling, localised at outer regions of the strand–strand interface, validating the non-invasive damage characterisation approach using a closed-rope configuration. This non-destructive spectroscopic technique offers a practical tool for monitoring internal fibre damage in high-performance aramid ropes, enabling improved preventive maintenance and more accurate service life predictions. • ATR-FTIR spectroscopy effectively tracks fatigue-induced damage progression in Twaron® ropes. • FTIR absorbance ratio (A 1110 / A 1514 ) correlates with internal damage progression. • Method enables rapid, non-invasive damage assessment across various rope sizes and constructions. • SEM and micro-CT imaging validate surface fibrillation and interfacial wear mechanisms.

Authors

Institutions

Publication Details

Journal
Polymer
Published
2025-10-18
DOI
https://doi.org/10.1016/j.polymer.2025.129224
Primary Topic
Polymer crystallization and properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing internal mechanical damage in aramid ropes using ATR-FTIR spectroscopy

Tanmaya Mishra, Matthijn de Rooij, Oday Allan
Polymer
Polymer crystallization and properties
article

Assessing internal mechanical damage in aramid ropes using ATR-FTIR spectroscopy

Tanmaya Mishra, Matthijn de Rooij, Oday Allan
article en

Abstract

We present a novel approach to use Attenuated Total Reflectance Fourier-Transform Infrared (ATR-FTIR) spectroscopy for assessing internal damage in Twaron® aramid ropes subjected to cyclic bending fatigue loading at various stages of the fatigue life. After testing, rope specimens were analysed under two configurations: (1) an “open-strand” configuration, where an individual strand was untwisted and isolated from a double-twisted three-strand rope to enable direct ATR measurement of the heavily damaged filaments, and (2) a “closed-rope” configuration, where measurements were conducted at the observable strand–strand interface, sampling a broader transverse region consisting of both highly and less-damaged filaments. The main aim of studying these two configurations was to evaluate ATR-FTIR as a non-destructive technique for internal damage characterisation in industrial aramid ropes. The effect of fibre orientation on FTIR spectra was examined to isolate it from the effect of mechanical damage on the spectra. FTIR spectral analysis involved normalising absorbance spectra to an internal reference band and tracking changes in peak intensity at 1110 cm -1 as a damage indicator. In open-strand measurements, the 1110 cm -1 absorbance showed a sharp initial decline before stabilising at higher damage levels. In contrast, closed-rope measurements exhibited a more gradual reduction, reflecting the averaging effect of mixed damage states across the measured region. A bounded exponential fit of the absorbance–damage relationship showed a strong correlation with damage progression, confirming that FTIR-derived peak absorbance ratios serve as reliable indicators of internal degradation. Moreover, changes in rope size (3- vs. 6-yarn strands) showed a minimal effect on spectral trends, supporting the scalability of the method to larger industrial ropes. Additional imaging using electron microscopy and computed tomography (CT) scanning revealed progressive fibrillation and peeling, localised at outer regions of the strand–strand interface, validating the non-invasive damage characterisation approach using a closed-rope configuration. This non-destructive spectroscopic technique offers a practical tool for monitoring internal fibre damage in high-performance aramid ropes, enabling improved preventive maintenance and more accurate service life predictions. • ATR-FTIR spectroscopy effectively tracks fatigue-induced damage progression in Twaron® ropes. • FTIR absorbance ratio (A 1110 / A 1514 ) correlates with internal damage progression. • Method enables rapid, non-invasive damage assessment across various rope sizes and constructions. • SEM and micro-CT imaging validate surface fibrillation and interfacial wear mechanisms.

PolymerVol. 340
University of Twente (NL)
Openalex Percentile: Top 74%
Polymer crystallization and properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.