Machine learning-optimized porous thermally responsive SS-PCM with switchable transparency for adaptive building envelope coatings

Buildings account for nearly 40 % of total energy consumption, with a significant share of heating and cooling demand arising from building envelopes. Conventional passive envelopes—such as cool roofs, radiative cooling surfaces, glazing systems, and passive solar walls—cannot automatically adapt to environmental conditions by switching between heating and cooling modes. To address this limitation, we propose a passive, adaptive building envelope coating system that responds to ambient temperature changes without external energy input. The system integrates solid–solid phase change materials (SS-PCM), Polydimethylsiloxane (PDMS) and Silver (Ag), enabling switchable radiative cooling and solar heating effects. We investigated the influence of porous structures on the optical and thermal performance of the SS-PCM system and implemented a machine learning-based optimization method to enhance its optical properties. The results: (1) confirmed that PDMS/SS-PCM/Ag coating system exhibits a switchable radiative cooling effect and a solar heating effect in response to the ambient temperature, while the net power exceeds that of the reference PDMS/Ag system by ∼ 250 W/ m 2 in heating mode; (2) indicated that random forest models can capture the complex relationships between the porous features and optical properties of the PDMS/SS-PCM/Ag systems, achieving prediction R 2 values greater than 0.8; and (3) identified two potentially optimized porous PDMS/SS-PCM/Ag coating systems, derived from machine learning analysis, each enhancing either the heating or the cooling power by 20–50 W/ m 2 compared to the non-porous PDMS/SS-PCM/Ag system.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-10-18
DOI
https://doi.org/10.1016/j.enbuild.2025.116593
Citations
2
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning-optimized porous thermally responsive SS-PCM with switchable transparency for adaptive building envelope coatings

Oren Mangoubi, Sergio Granados-Fócil, Steven Van Dessel, Mingjiang Tao et al.
2 citations
Energy and Buildings
Thermal Radiation and Cooling Technologies
1.91
article

Machine learning-optimized porous thermally responsive SS-PCM with switchable transparency for adaptive building envelope coatings

Oren Mangoubi, Sergio Granados-Fócil, Steven Van Dessel, Mingjiang Tao, Zhiying Xiao, Rajae Bousselham
article en
2 citations

Abstract

Buildings account for nearly 40 % of total energy consumption, with a significant share of heating and cooling demand arising from building envelopes. Conventional passive envelopes—such as cool roofs, radiative cooling surfaces, glazing systems, and passive solar walls—cannot automatically adapt to environmental conditions by switching between heating and cooling modes. To address this limitation, we propose a passive, adaptive building envelope coating system that responds to ambient temperature changes without external energy input. The system integrates solid–solid phase change materials (SS-PCM), Polydimethylsiloxane (PDMS) and Silver (Ag), enabling switchable radiative cooling and solar heating effects. We investigated the influence of porous structures on the optical and thermal performance of the SS-PCM system and implemented a machine learning-based optimization method to enhance its optical properties. The results: (1) confirmed that PDMS/SS-PCM/Ag coating system exhibits a switchable radiative cooling effect and a solar heating effect in response to the ambient temperature, while the net power exceeds that of the reference PDMS/Ag system by ∼ 250 W/ m 2 in heating mode; (2) indicated that random forest models can capture the complex relationships between the porous features and optical properties of the PDMS/SS-PCM/Ag systems, achieving prediction R 2 values greater than 0.8; and (3) identified two potentially optimized porous PDMS/SS-PCM/Ag coating systems, derived from machine learning analysis, each enhancing either the heating or the cooling power by 20–50 W/ m 2 compared to the non-porous PDMS/SS-PCM/Ag system.

Energy and BuildingsVol. 349
Worcester Polytechnic Institute (US), National Laboratory of the Rockies (US), Clark University (US)
Openalex Percentile: Top 13%
Thermal Radiation and Cooling Technologies
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.