Air-recirculating Earth-to-Air Heat Exchangers for efficient HVAC: Energy and environmental analysis in school and residential buildings

This study investigates the energy and economic performance of a hybrid HVAC system that integrates an Earth-to-Air Heat Exchanger (EAHE) operating in both open loop and semi-closed loop configurations. The system, placed upstream of a conventional Air Handling Unit (AHU), is analyzed as a passive strategy for pre-conditioning intake air in different building scenarios. A detailed numerical model, based on the finite element method and validated against literature data, is used to simulate transient heat and moisture transfer in buried ducts under realistic climatic and occupancy conditions. Two typical applications—a residential and a school building located in Shanghai—are evaluated in both heating and cooling modes. The results show that coupling the EAHE to the HVAC system can yield substantial seasonal energy savings: up to 52% for school buildings and 71% for residential ones during heating. In cooling mode, although savings are lower, the integration of the EAHE into the HVAC system remains beneficial, especially during high ventilation demand. The semi-closed loop configuration, which combines outdoor and recirculated air, improves inlet air stability and reduces peak loads, while maintaining comparable energy savings. From an economic standpoint, the open loop configuration proves more cost-effective, achieving a Simple Payback Period in open-loop of 3.2 years and of 2.0 years respectively in school and residential cases. The findings demonstrate the potential of hybrid EAHE systems—operating in both open and semi-closed loops—as scalable, cost-effective solutions to improve HVAC performance and reduce carbon emissions in buildings. • Hybrid HVAC system with earth-to-air heat exchanger is numerically assessed • School and residential buildings studied in heating and cooling modes • Open and semi-closed loop systems compared in terms of energy performance • Seasonal energy savings up to 71% with earth-to-air heat exchanger • Air recirculation lowers power demand while maintaining similar savings

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-10-18
DOI
https://doi.org/10.1016/j.jobe.2025.114403
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air-recirculating Earth-to-Air Heat Exchangers for efficient HVAC: Energy and environmental analysis in school and residential buildings

Claudia Masselli, Adriana Greco, Luca Cirillo, Vincenzo Orabona et al.
Journal of Building Engineering
Geothermal Energy Systems and Applications
article

Air-recirculating Earth-to-Air Heat Exchangers for efficient HVAC: Energy and environmental analysis in school and residential buildings

Claudia Masselli, Adriana Greco, Luca Cirillo, Vincenzo Orabona, Lucrezia Verneau, Sabrina Gargiulo
article en

Abstract

This study investigates the energy and economic performance of a hybrid HVAC system that integrates an Earth-to-Air Heat Exchanger (EAHE) operating in both open loop and semi-closed loop configurations. The system, placed upstream of a conventional Air Handling Unit (AHU), is analyzed as a passive strategy for pre-conditioning intake air in different building scenarios. A detailed numerical model, based on the finite element method and validated against literature data, is used to simulate transient heat and moisture transfer in buried ducts under realistic climatic and occupancy conditions. Two typical applications—a residential and a school building located in Shanghai—are evaluated in both heating and cooling modes. The results show that coupling the EAHE to the HVAC system can yield substantial seasonal energy savings: up to 52% for school buildings and 71% for residential ones during heating. In cooling mode, although savings are lower, the integration of the EAHE into the HVAC system remains beneficial, especially during high ventilation demand. The semi-closed loop configuration, which combines outdoor and recirculated air, improves inlet air stability and reduces peak loads, while maintaining comparable energy savings. From an economic standpoint, the open loop configuration proves more cost-effective, achieving a Simple Payback Period in open-loop of 3.2 years and of 2.0 years respectively in school and residential cases. The findings demonstrate the potential of hybrid EAHE systems—operating in both open and semi-closed loops—as scalable, cost-effective solutions to improve HVAC performance and reduce carbon emissions in buildings. • Hybrid HVAC system with earth-to-air heat exchanger is numerically assessed • School and residential buildings studied in heating and cooling modes • Open and semi-closed loop systems compared in terms of energy performance • Seasonal energy savings up to 71% with earth-to-air heat exchanger • Air recirculation lowers power demand while maintaining similar savings

Journal of Building EngineeringVol. 116
University of Naples Federico II (IT)
Openalex Percentile: Top 80%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.