Spatially Patterned Grid Optodes for Simultaneous Multiparameter Chemical Imaging

High-resolution imaging of chemical gradients is critical for studying complex microscale environments, but conventional planar optodes face limitations in simultaneous multiparameter sensing due to spectral crosstalk and signal overlap. Here, we present a modular alternative using grid optodes─arrays of discrete, selectively responsive sensor spots printed in a checkerboard layout via a custom 3D-printed dispensing system. Each spot responds to either oxygen or pH, enabling parallel detection with minimal optical interference and achieving spatial resolution below 650 μm. Optical readout was performed using standard RGB cameras, and multiple spatial interpolation methods were evaluated to reconstruct continuous 2D analyte maps from discrete spot data. Nearest-neighbor interpolation followed by mean filtering provided robust image reconstruction. The grid optodes were validated in structured agar matrices and sulfidic sediment, demonstrating imaging performance comparable to conventional planar optodes. This approach offers a scalable, low-cost platform for high-resolution, multiparameter chemical imaging compatible with accessible RGB detection systems and adaptable to diverse sensing applications.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-10-18
DOI
https://doi.org/10.1021/acssensors.5c02007
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatially Patterned Grid Optodes for Simultaneous Multiparameter Chemical Imaging

Jacek Fiutowski, Casper Kunstmann‐Olsen, Klaus Koren, Andrey V. Kalinichev et al.
ACS Sensors
Atomic and Subatomic Physics Research
article

Spatially Patterned Grid Optodes for Simultaneous Multiparameter Chemical Imaging

Jacek Fiutowski, Casper Kunstmann‐Olsen, Klaus Koren, Andrey V. Kalinichev, Martin Reinhard Rasmussen, Felix L. Hoch, Zuzanna Parnicka
article en

Abstract

High-resolution imaging of chemical gradients is critical for studying complex microscale environments, but conventional planar optodes face limitations in simultaneous multiparameter sensing due to spectral crosstalk and signal overlap. Here, we present a modular alternative using grid optodes─arrays of discrete, selectively responsive sensor spots printed in a checkerboard layout via a custom 3D-printed dispensing system. Each spot responds to either oxygen or pH, enabling parallel detection with minimal optical interference and achieving spatial resolution below 650 μm. Optical readout was performed using standard RGB cameras, and multiple spatial interpolation methods were evaluated to reconstruct continuous 2D analyte maps from discrete spot data. Nearest-neighbor interpolation followed by mean filtering provided robust image reconstruction. The grid optodes were validated in structured agar matrices and sulfidic sediment, demonstrating imaging performance comparable to conventional planar optodes. This approach offers a scalable, low-cost platform for high-resolution, multiparameter chemical imaging compatible with accessible RGB detection systems and adaptable to diverse sensing applications.

ACS SensorsVol. 10(11)
University of Southern Denmark (DK), Aarhus University (DK)
Openalex Percentile: Top 76%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.