Characterizing solute transport across cell layers: Artifact correction and parameter extraction from a simplified three-compartment model

Quantifying solute transport across epithelial cell layers grown on transwell inserts is a common approach in early-stage drug development to estimate pharmacokinetic properties such as absorption and bioavailability. To increase throughput and reduce variability, these assays are increasingly automated, including the use of robotic or microfluidic systems for time-resolved sampling. However, both automated and manual sampling can introduce systematic artifacts, such as residual volume retention and surface adsorption, that distort concentration time series and affect downstream analysis. To fully realize the potential precision of automated measurements, we propose a mathematical correction to account for sampling artifacts; then, to fit the corrected data to a three-compartment model that captures membrane diffusion, cellular sequestration, and metabolic loss. The method is demonstrated on datasets from transwell epithelial barrier transport assays. We suggest that the considered three-compartment model yields mechanistically more meaningful parameters than the conventional apparent permeability (Papp) measure. The proposed approach thus enables more accurate characterization of analyte interactions with the barrier cell layer, supporting better-informed assessments of compound behavior in vitro transport systems. Quantifying solute transport across epithelial cell layers grown on transwell inserts is a common approach in early-stage drug development to estimate pharmacokinetic properties such as absorption and bioavailability. To increase throughput and reduce variability, these assays are increasingly automated, including the use of robotic or microfluidic systems for time-resolved sampling. However, both automated and manual sampling can introduce systematic artifacts, such as residual volume retention and surface adsorption, that distort concentration time series and affect downstream analysis. To fully realize the potential precision of automated measurements, we propose a mathematical correction to account for sampling artifacts; then, to fit the corrected data to a three-compartment model that captures membrane diffusion, cellular sequestration, and metabolic loss. The method is demonstrated on datasets from transwell epithelial barrier transport assays. We suggest that the considered three-compartment model yields mechanistically more meaningful parameters than the conventional apparent permeability (Papp) measure. The proposed approach thus enables more accurate characterization of analyte interactions with the barrier cell layer, supporting better-informed assessments of compound behavior in vitro transport systems.

Authors

Institutions

Publication Details

Journal
European Journal of Pharmaceutical Sciences
Published
2025-10-14
DOI
https://doi.org/10.1016/j.ejps.2025.107323
Citations
1
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing solute transport across cell layers: Artifact correction and parameter extraction from a simplified three-compartment model

Szilvia Bősze, Júlia Tárnoki-Zách, Imre Boldizsár, Balázs Döme et al.
1 citations
European Journal of Pharmaceutical Sciences
Groundwater flow and contamination studies
0.80
article

Characterizing solute transport across cell layers: Artifact correction and parameter extraction from a simplified three-compartment model

Szilvia Bősze, Júlia Tárnoki-Zách, Imre Boldizsár, Balázs Döme, András Czirók, Gábor M. Kovács
article en
1 citations

Abstract

Quantifying solute transport across epithelial cell layers grown on transwell inserts is a common approach in early-stage drug development to estimate pharmacokinetic properties such as absorption and bioavailability. To increase throughput and reduce variability, these assays are increasingly automated, including the use of robotic or microfluidic systems for time-resolved sampling. However, both automated and manual sampling can introduce systematic artifacts, such as residual volume retention and surface adsorption, that distort concentration time series and affect downstream analysis. To fully realize the potential precision of automated measurements, we propose a mathematical correction to account for sampling artifacts; then, to fit the corrected data to a three-compartment model that captures membrane diffusion, cellular sequestration, and metabolic loss. The method is demonstrated on datasets from transwell epithelial barrier transport assays. We suggest that the considered three-compartment model yields mechanistically more meaningful parameters than the conventional apparent permeability (Papp) measure. The proposed approach thus enables more accurate characterization of analyte interactions with the barrier cell layer, supporting better-informed assessments of compound behavior in vitro transport systems. Quantifying solute transport across epithelial cell layers grown on transwell inserts is a common approach in early-stage drug development to estimate pharmacokinetic properties such as absorption and bioavailability. To increase throughput and reduce variability, these assays are increasingly automated, including the use of robotic or microfluidic systems for time-resolved sampling. However, both automated and manual sampling can introduce systematic artifacts, such as residual volume retention and surface adsorption, that distort concentration time series and affect downstream analysis. To fully realize the potential precision of automated measurements, we propose a mathematical correction to account for sampling artifacts; then, to fit the corrected data to a three-compartment model that captures membrane diffusion, cellular sequestration, and metabolic loss. The method is demonstrated on datasets from transwell epithelial barrier transport assays. We suggest that the considered three-compartment model yields mechanistically more meaningful parameters than the conventional apparent permeability (Papp) measure. The proposed approach thus enables more accurate characterization of analyte interactions with the barrier cell layer, supporting better-informed assessments of compound behavior in vitro transport systems.

European Journal of Pharmaceutical SciencesVol. 215
Semmelweis University (HU), Eötvös Loránd University (HU)
Openalex Percentile: Top 24%
Groundwater flow and contamination studies
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.