Ultra-low thickness bio-degradable polymer vs durable polymer everolimus eluting stents – A 24 months clinical follow-up study

A multicenter observational study of 2059 PCI patients compared the ultrathin-strut BDP-EES (Eternia) with the DP-EES (Xience) over 24 months. Patients in the Eternia group were older with more chronic total occlusions. MACE rates were 3.7 % (Xience) vs 3.8 % (Eternia; p = 0.939), with no significant differences in mortality, TVR, or stent thrombosis. No definite or probable stent thrombosis was reported in either group, and possible thrombosis rates were low (0.3 % vs 0.4 %). These findings suggest that biodegradable and durable polymer platforms offer similar long-term performance. The Eternia stents demonstrated equivalent safety and efficacy to Xience stents at 24 months.

Authors

Institutions

Publication Details

Journal
Indian Heart Journal
Published
2025-10-15
DOI
https://doi.org/10.1016/j.ihj.2025.10.005
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-low thickness bio-degradable polymer vs durable polymer everolimus eluting stents – A 24 months clinical follow-up study

Rohit Chopra, Rahul Gupta, Pushpendra Kumar Garg, U Kaul et al.
Indian Heart Journal
Coronary Interventions and Diagnostics
article

Ultra-low thickness bio-degradable polymer vs durable polymer everolimus eluting stents – A 24 months clinical follow-up study

Rohit Chopra, Rahul Gupta, Pushpendra Kumar Garg, U Kaul, Vivek Mathur
article en

Abstract

A multicenter observational study of 2059 PCI patients compared the ultrathin-strut BDP-EES (Eternia) with the DP-EES (Xience) over 24 months. Patients in the Eternia group were older with more chronic total occlusions. MACE rates were 3.7 % (Xience) vs 3.8 % (Eternia; p = 0.939), with no significant differences in mortality, TVR, or stent thrombosis. No definite or probable stent thrombosis was reported in either group, and possible thrombosis rates were low (0.3 % vs 0.4 %). These findings suggest that biodegradable and durable polymer platforms offer similar long-term performance. The Eternia stents demonstrated equivalent safety and efficacy to Xience stents at 24 months.

Indian Heart JournalVol. 77(6)
Art Research Centre of the Slovak Academy of Sciences (SK), Shree Krishna Hospital (IN), Batra Hospital and Medical Research Centre (IN), Mittal hospital (IN)
Openalex Percentile: Top 54%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.