51st Annual Conference of the International Society for Pediatric and Adolescent Diabetes (ISPAD): Abstracts

Introduction: AID systems are currently the most effective therapy for patients with T1D. Real-world studies on the use of tubeless AID systems are still limited in Italy. Objectives: To assess the effectiveness, safety, and user settings of a tubeless automated insulin delivery (AID) system in pediatric patients aged 2–18 years with type 1 diabetes (T1D) previously treated with multiple daily injections (MDI) or sensor-augmented pump (SAP). Methods: This multicenter, prospective, observational study was conducted by the ISPED Diabetes Study Group with a planned 12-month follow-up. Preliminary data analysis was conducted on clinical and glycemic data collected at initiation (T0), and after 1 (T1) and 3 months (T2). A total of 214 patients from 12 Italian centers were included; 180 completed the 1-month and 124 the 3-month visit. Continuous variables were described as mean (SD) or median (IQR); categorical variables as frequencies and percentages. Differences were tested using Wilcoxon signed-rank test; p<0.05 was considered significant. Results: Mean age of participant included in the study was 13.65±3.41 years; 50.5% were female and 95.3% were Caucasian. At baseline, 40.8% were on MDI and 59.2% on SAP. 1-month after the system initiation glycemic control improved significantly, with TIR increasing from 55.87% to 70.79% (+14.92%, p<0.001), TITR from 35.28% to 45.99% (+10.71%, p<0.001), and TBR decreasing from 3.46% to 2.25% (p<0.001). These results were substantially maintained at 3 months (TIR 70.77%±9.7, TITR 46.71%±10.68, TBR 2.03%±2.39), together with a significant reduction in HbA1c (-0.36%, from 7.20±0.75% to 6.84±0.68%, p<0.001) and no significant change in total daily insulin requirement. A single glucose target was set in 84.6% of patients, most frequently 110 mg/dL (61.7%). Conclusions: Preliminary real-world data show that this tubeless AID system is effective and safe, achieving rapid and sustained improvements in glycemic control in Italian pediatric patients with T1D during the first three months of use.

Publication Details

Journal
Hormone Research in Paediatrics
Published
2025-10-17
DOI
https://doi.org/10.1159/000548269
Citations
1
Primary Topic
Diabetes and associated disorders
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

51st Annual Conference of the International Society for Pediatric and Adolescent Diabetes (ISPAD): Abstracts

1 citations
Hormone Research in Paediatrics
Diabetes and associated disorders
1.82
article

51st Annual Conference of the International Society for Pediatric and Adolescent Diabetes (ISPAD): Abstracts

article en
1 citations

Abstract

Introduction: AID systems are currently the most effective therapy for patients with T1D. Real-world studies on the use of tubeless AID systems are still limited in Italy. Objectives: To assess the effectiveness, safety, and user settings of a tubeless automated insulin delivery (AID) system in pediatric patients aged 2–18 years with type 1 diabetes (T1D) previously treated with multiple daily injections (MDI) or sensor-augmented pump (SAP). Methods: This multicenter, prospective, observational study was conducted by the ISPED Diabetes Study Group with a planned 12-month follow-up. Preliminary data analysis was conducted on clinical and glycemic data collected at initiation (T0), and after 1 (T1) and 3 months (T2). A total of 214 patients from 12 Italian centers were included; 180 completed the 1-month and 124 the 3-month visit. Continuous variables were described as mean (SD) or median (IQR); categorical variables as frequencies and percentages. Differences were tested using Wilcoxon signed-rank test; p<0.05 was considered significant. Results: Mean age of participant included in the study was 13.65±3.41 years; 50.5% were female and 95.3% were Caucasian. At baseline, 40.8% were on MDI and 59.2% on SAP. 1-month after the system initiation glycemic control improved significantly, with TIR increasing from 55.87% to 70.79% (+14.92%, p<0.001), TITR from 35.28% to 45.99% (+10.71%, p<0.001), and TBR decreasing from 3.46% to 2.25% (p<0.001). These results were substantially maintained at 3 months (TIR 70.77%±9.7, TITR 46.71%±10.68, TBR 2.03%±2.39), together with a significant reduction in HbA1c (-0.36%, from 7.20±0.75% to 6.84±0.68%, p<0.001) and no significant change in total daily insulin requirement. A single glucose target was set in 84.6% of patients, most frequently 110 mg/dL (61.7%). Conclusions: Preliminary real-world data show that this tubeless AID system is effective and safe, achieving rapid and sustained improvements in glycemic control in Italian pediatric patients with T1D during the first three months of use.

Hormone Research in PaediatricsVol. 98(Suppl. 4)
Openalex Percentile: Top 12%
Diabetes and associated disorders
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.