Localized corrosion monitoring and quantitative evaluation of steel wires in the splay saddle using distributed optical fiber sensing technology

Steel wires in the splay saddle of suspension bridges are highly susceptible to corrosion due to a highly exposed environment, moisture, and corrosive media retention, and limitations of protective measures. Existing optical fiber strain monitoring (using conventional spiral-wrapping) fails to quantify corrosion on small-diameter wires. This study optimizes a corrosion-resistant fiber deployment scheme. Accelerated corrosion tests with customized wire tensioning device reveal that wire corrosion creates cross-sectional discontinuities, forming high-stress zones with a diagnostic bimodal strain distribution for precise corrosion localization. Corrosion zone strain evolution shows three stages—uniform, non-uniform, and critical fracture—quantified by strain heterogeneity. Key influences include initial strain, corrosion length/rate, and load variations. A quantitative theoretical model linking fiber strain response to corrosion degree was established, incorporating a correction factor K to reduce maximum average relative error to <3%. This enables distributed optical fiber sensing to accurately assess steel wire corrosion severity.

Authors

Institutions

Publication Details

Journal
Structural Health Monitoring
Published
2025-10-17
DOI
https://doi.org/10.1177/14759217251382101
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Localized corrosion monitoring and quantitative evaluation of steel wires in the splay saddle using distributed optical fiber sensing technology

Nianchun Deng, Liang Fan, Zhong‐Yuan Lu, Qi Fan et al.
Structural Health Monitoring
Advanced Fiber Optic Sensors
article

Localized corrosion monitoring and quantitative evaluation of steel wires in the splay saddle using distributed optical fiber sensing technology

Nianchun Deng, Liang Fan, Zhong‐Yuan Lu, Qi Fan, Wei Shen
article en

Abstract

Steel wires in the splay saddle of suspension bridges are highly susceptible to corrosion due to a highly exposed environment, moisture, and corrosive media retention, and limitations of protective measures. Existing optical fiber strain monitoring (using conventional spiral-wrapping) fails to quantify corrosion on small-diameter wires. This study optimizes a corrosion-resistant fiber deployment scheme. Accelerated corrosion tests with customized wire tensioning device reveal that wire corrosion creates cross-sectional discontinuities, forming high-stress zones with a diagnostic bimodal strain distribution for precise corrosion localization. Corrosion zone strain evolution shows three stages—uniform, non-uniform, and critical fracture—quantified by strain heterogeneity. Key influences include initial strain, corrosion length/rate, and load variations. A quantitative theoretical model linking fiber strain response to corrosion degree was established, incorporating a correction factor K to reduce maximum average relative error to <3%. This enables distributed optical fiber sensing to accurately assess steel wire corrosion severity.

Structural Health Monitoring
Guangxi University (CN), Institute of Oceanology (CN)
Openalex Percentile: Top 70%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.