Comparison of outcomes in robot-assisted colon cancer surgery using Da Vinci Xi, Hugo™ RAS, and Versius®: The COMPAR-CRC multiplatform study

Since the introduction of the da Vinci® robotic system, robot-assisted colon resection has gained popularity because of its the potential technical advantages. Recently, two new CE-marked platforms have become available in Europe: Hugo™ RAS and Versius®. We present the first prospective case series comparing these three robotic systems. This exploratory, prospective study enrolled 45 consecutive adult patients undergoing robotic colon resection between February and December 2024, as part of the COMPAR trial. Two experienced colorectal surgeons performed all procedures across two surgical units. Each robotic platform was used in 15 cases. The primary outcomes were conversion to laparoscopy or open surgery and intra-operative complications. The secondary outcomes included post-operative recovery, oncological results, and platform-specific technical parameters. The mean age was 66.8 years and 68.9% of patients underwent surgery for colon cancer. No conversions occurred in the da Vinci group, whereas 2 and 3 conversions to laparoscopy were recorded with Hugo™ RAS and Versius®, respectively. One intra-operative instrument malfunction occurred with Hugo™ RAS, and one surgical complication was reported in each group. No significant differences emerged in post-operative recovery or oncological outcomes. Versius® cases required more frequent use of laparoscopic energy devices ( p < 0.001). Hugo™ RAS was associated with a longer total operating room time ( p = 0.022) and longer incision length ( p = 0.005). Robotic colorectal surgery with all three platforms is feasible when performed by expert surgeons. While early outcomes are encouraging, larger comparative trials are needed to confirm differences in recovery and oncological efficacy.

Authors

Institutions

Publication Details

Journal
Laparoscopic Endoscopic and Robotic Surgery
Published
2025-10-17
DOI
https://doi.org/10.1016/j.lers.2025.10.001
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of outcomes in robot-assisted colon cancer surgery using Da Vinci Xi, Hugo™ RAS, and Versius®: The COMPAR-CRC multiplatform study

Corrado Pedrazzani, Ernesto De Giulio, Simone Priolo, Andrea Ruzzenente et al.
Laparoscopic Endoscopic and Robotic Surgery
Colorectal Cancer Surgical Treatments
article

Comparison of outcomes in robot-assisted colon cancer surgery using Da Vinci Xi, Hugo™ RAS, and Versius®: The COMPAR-CRC multiplatform study

Corrado Pedrazzani, Ernesto De Giulio, Simone Priolo, Andrea Ruzzenente, Giulia Turri, Alessandro Valdegamberi, Andrea Ballarin, Michele Genna, Carlo Andrea Bravi, Ruben Sciortino
article en

Abstract

Since the introduction of the da Vinci® robotic system, robot-assisted colon resection has gained popularity because of its the potential technical advantages. Recently, two new CE-marked platforms have become available in Europe: Hugo™ RAS and Versius®. We present the first prospective case series comparing these three robotic systems. This exploratory, prospective study enrolled 45 consecutive adult patients undergoing robotic colon resection between February and December 2024, as part of the COMPAR trial. Two experienced colorectal surgeons performed all procedures across two surgical units. Each robotic platform was used in 15 cases. The primary outcomes were conversion to laparoscopy or open surgery and intra-operative complications. The secondary outcomes included post-operative recovery, oncological results, and platform-specific technical parameters. The mean age was 66.8 years and 68.9% of patients underwent surgery for colon cancer. No conversions occurred in the da Vinci group, whereas 2 and 3 conversions to laparoscopy were recorded with Hugo™ RAS and Versius®, respectively. One intra-operative instrument malfunction occurred with Hugo™ RAS, and one surgical complication was reported in each group. No significant differences emerged in post-operative recovery or oncological outcomes. Versius® cases required more frequent use of laparoscopic energy devices ( p < 0.001). Hugo™ RAS was associated with a longer total operating room time ( p = 0.022) and longer incision length ( p = 0.005). Robotic colorectal surgery with all three platforms is feasible when performed by expert surgeons. While early outcomes are encouraging, larger comparative trials are needed to confirm differences in recovery and oncological efficacy.

Laparoscopic Endoscopic and Robotic SurgeryVol. 8(4)
University of Verona (IT), University Hospital Foundation (CA)
Openalex Percentile: Top 60%
Colorectal Cancer Surgical Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.