Photovoltaic system design under uncertain building operation profiles: A techno-economic analysis in an extreme hot climate

The growing global demand for energy and the environmental impact of fossil fuel-based electricity generation have accelerated the adoption of renewable energy solutions, with photovoltaic (PV) systems playing a pivotal role. However, their successful integration is often challenged by uncertainty in building energy use, which can vary widely depending on how buildings are operated. This study examines the impact of various energy consumption patterns on the performance and cost-effectiveness of photovoltaic (PV) systems in three types of commercial buildings in Abu Dhabi, UAE: a hotel, a medium-sized office, and a small office. Using advanced simulation tools (EnergyPlus and SAM), 27 different scenarios were analyzed based on three user behavior profiles: energy-saving (Austere), typical (Baseline), and energy-intensive (Wasteful). The results show a wide range in energy demand, from 11.4 GWh to 21.18 GWh per year—an increase of 86% between the most and least efficient profiles. The Levelized Cost of Energy (LCOE) also varied, rising from 18.4 to 21.5 ¢/kWh under less efficient conditions, resulting in a 17% increase. These findings suggest that relying solely on PV may not be sufficient for high-consumption buildings and that poor energy practices can significantly increase system costs, even in smaller buildings. Notably, the lowest LCOE is achieved in a mixed-demand scenario that combines a Baseline hotel, a Wasteful medium office, and an Austere small office, underscoring the strategic value of targeted demand management across building types to minimize system-wide costs. The scenario-based modeling approach enables realistic assessment of PV system cost-effectiveness under variable operational behaviors, offering more actionable insights than fixed-demand models. • Scenario-based modeling improves PV planning under demand uncertainty • PV system costs rise 17% under inefficient building operation scenarios • Mixed-use demand profiles yield the lowest LCOE in extreme hot climates • PV alone meets only ∼3% of annual demand in high-consumption buildings

Authors

Institutions

Publication Details

Journal
Cleaner Engineering and Technology
Published
2025-10-17
DOI
https://doi.org/10.1016/j.clet.2025.101091
Primary Topic
Solar Radiation and Photovoltaics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photovoltaic system design under uncertain building operation profiles: A techno-economic analysis in an extreme hot climate

Elie Azar, Ahmad Mayyas, Nourah Alkaabi
Cleaner Engineering and Technology
Solar Radiation and Photovoltaics
article

Photovoltaic system design under uncertain building operation profiles: A techno-economic analysis in an extreme hot climate

Elie Azar, Ahmad Mayyas, Nourah Alkaabi
article en

Abstract

The growing global demand for energy and the environmental impact of fossil fuel-based electricity generation have accelerated the adoption of renewable energy solutions, with photovoltaic (PV) systems playing a pivotal role. However, their successful integration is often challenged by uncertainty in building energy use, which can vary widely depending on how buildings are operated. This study examines the impact of various energy consumption patterns on the performance and cost-effectiveness of photovoltaic (PV) systems in three types of commercial buildings in Abu Dhabi, UAE: a hotel, a medium-sized office, and a small office. Using advanced simulation tools (EnergyPlus and SAM), 27 different scenarios were analyzed based on three user behavior profiles: energy-saving (Austere), typical (Baseline), and energy-intensive (Wasteful). The results show a wide range in energy demand, from 11.4 GWh to 21.18 GWh per year—an increase of 86% between the most and least efficient profiles. The Levelized Cost of Energy (LCOE) also varied, rising from 18.4 to 21.5 ¢/kWh under less efficient conditions, resulting in a 17% increase. These findings suggest that relying solely on PV may not be sufficient for high-consumption buildings and that poor energy practices can significantly increase system costs, even in smaller buildings. Notably, the lowest LCOE is achieved in a mixed-demand scenario that combines a Baseline hotel, a Wasteful medium office, and an Austere small office, underscoring the strategic value of targeted demand management across building types to minimize system-wide costs. The scenario-based modeling approach enables realistic assessment of PV system cost-effectiveness under variable operational behaviors, offering more actionable insights than fixed-demand models. • Scenario-based modeling improves PV planning under demand uncertainty • PV system costs rise 17% under inefficient building operation scenarios • Mixed-use demand profiles yield the lowest LCOE in extreme hot climates • PV alone meets only ∼3% of annual demand in high-consumption buildings

Cleaner Engineering and TechnologyVol. 29
Khalifa University of Science and Technology (AE), Carleton University (CA)
Openalex Percentile: Top 84%
Solar Radiation and Photovoltaics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.