High-Fidelity MicroCT Reconstructions of Cardiac Devices Enable Patient-Specific Simulation for Structural Heart Interventions

<b>Background/Objective</b>: Precise preprocedural planning is essential for the safety and efficacy of structural heart interventions. Conventional imaging modalities, while informative, do not allow for direct and accurate visualization, limiting procedural predictability. We aimed to develop and validate a high-resolution micro-computed tomography (microCT)-based reverse modeling workflow that integrates digital reconstructions of metallic cardiac devices into patient imaging datasets, enabling accurate, patient-specific virtual simulation for procedural planning. <b>Methods</b>: Clinical-grade transcatheter heart valves, septal defect occluders, patent ductus arteriosus occluders, left atrial appendage closure devices, and coronary stents were scanned using microCT (36.9 μm resolution). Agreement was assessed by intra-class correlation coefficients (ICC) and Bland-Altman analyses. Device geometries were reconstructed into 3D stereolithography files and virtually implanted within multislice CT datasets using dedicated software. <b>Results</b>: Devices were successfully reverse-modeled with high geometric fidelity, showing negligible dimensional deviations from manufacturer specifications (mean ΔDistance range: -0.20 to +0.20 mm). Simulated measurements demonstrated excellent concordance with postprocedural imaging (ICC 0.90-0.96). The workflow accurately predicted clinically relevant parameters such as valve-to-coronary distances and implantation depths. Notably, preprocedural simulation identified a case at high risk of coronary obstruction, confirmed clinically and managed successfully. <b>Conclusions</b>: The microCT-based reverse modeling workflow offers a rapid, reproducible, and clinically relevant method for patient-specific simulation in structural heart interventions. By preserving anatomical fidelity and providing detailed device-tissue spatial visualization, this approach enhances preprocedural planning accuracy, risk stratification, and procedural safety. Its resource-efficient digital nature facilitates broad adoption and iterative simulation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-10-17
DOI
https://doi.org/10.3390/jcm14207341
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Fidelity MicroCT Reconstructions of Cardiac Devices Enable Patient-Specific Simulation for Structural Heart Interventions

Zhongkai Zhu, Yong Peng, Yong Chen, Yaojia Zhou et al.
Journal of Clinical Medicine
Advanced X-ray and CT Imaging
article

High-Fidelity MicroCT Reconstructions of Cardiac Devices Enable Patient-Specific Simulation for Structural Heart Interventions

Zhongkai Zhu, Yong Peng, Yong Chen, Yaojia Zhou, Mao Chen, Yuan Feng
article en

Abstract

<b>Background/Objective</b>: Precise preprocedural planning is essential for the safety and efficacy of structural heart interventions. Conventional imaging modalities, while informative, do not allow for direct and accurate visualization, limiting procedural predictability. We aimed to develop and validate a high-resolution micro-computed tomography (microCT)-based reverse modeling workflow that integrates digital reconstructions of metallic cardiac devices into patient imaging datasets, enabling accurate, patient-specific virtual simulation for procedural planning. <b>Methods</b>: Clinical-grade transcatheter heart valves, septal defect occluders, patent ductus arteriosus occluders, left atrial appendage closure devices, and coronary stents were scanned using microCT (36.9 μm resolution). Agreement was assessed by intra-class correlation coefficients (ICC) and Bland-Altman analyses. Device geometries were reconstructed into 3D stereolithography files and virtually implanted within multislice CT datasets using dedicated software. <b>Results</b>: Devices were successfully reverse-modeled with high geometric fidelity, showing negligible dimensional deviations from manufacturer specifications (mean ΔDistance range: -0.20 to +0.20 mm). Simulated measurements demonstrated excellent concordance with postprocedural imaging (ICC 0.90-0.96). The workflow accurately predicted clinically relevant parameters such as valve-to-coronary distances and implantation depths. Notably, preprocedural simulation identified a case at high risk of coronary obstruction, confirmed clinically and managed successfully. <b>Conclusions</b>: The microCT-based reverse modeling workflow offers a rapid, reproducible, and clinically relevant method for patient-specific simulation in structural heart interventions. By preserving anatomical fidelity and providing detailed device-tissue spatial visualization, this approach enhances preprocedural planning accuracy, risk stratification, and procedural safety. Its resource-efficient digital nature facilitates broad adoption and iterative simulation.

Journal of Clinical MedicineVol. 14(20)
Sichuan University (CN), West China Hospital of Sichuan University (CN)
National Natural Science Foundation of China, Sichuan University, West China Hospital, Sichuan University
Openalex Percentile: Top 71%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.